Power, wavelength, beam profile, safety
Laser Power & Stability Measurement
- TS2+TP100: Optical power range: 2 mW - 2 W; Wavelength range: 0.19-25 μm; Active area: 22 mm
- TS5+TP100: Optical power range: 2 mW - 5 W; Wavelength range: 0.19-25 μm; Active area: 22 mm
- TS15+TP100: Optical power range: 2 mW - 15 W; Wavelength range: 0.19-25 μm; Active area: 22 mm
- TS35+TP100: Optical power range: 10 mW - 35 W; Wavelength range: 0.19-25 μm; Active area: 22 mm
- TS50+TP100: Optical power range: 10 mW - 50 W; Wavelength range: 0.19-25 μm; Active area: 22 mm
- TS100+TP100: Optical power range: 0.5 W - 100 W; Wavelength range: 0.19-25 μm; Active area: 25 mm

Explore the hardware
A closer look at each measurement family
Explore the sensor and readout configurations, then open a model for its photos, dimensional drawings and datasheet. Shared housings are shown for the corresponding series; ratings remain model specific.

TS thermopile power meters
Broadband sensor heads for low to high optical power.
View TS2+TP100
HS sensitive thermopile power meters
Sensitive thermal detection for lower-power beams.
View HS1+TP100
Handheld power meters
Portable measurement with an integrated display.
View HP2
Photodiode power meters
Wavelength-specific sensors with defined attenuation limits.
View PD100-350+TP100
Integrating-sphere power meters
Sphere-based collection for compatible laser beams.
View PD3000-350+TP100
USB power meters
PC acquisition with sensor, display and software views.
View TS2-USBProduct Specifications
Laser Power & Stability Measurement
48 specification rows
TS thermopile power meters
| Model and datasheet | Optical power range | Wavelength range | Active area |
|---|---|---|---|
| TS2+TP100Datasheet(opens in a new tab) | 2 mW - 2 W | 0.19-25 μm | 22 mm |
| TS5+TP100Datasheet(opens in a new tab) | 2 mW - 5 W | 0.19-25 μm | 22 mm |
| TS15+TP100Datasheet(opens in a new tab) | 2 mW - 15 W | 0.19-25 μm | 22 mm |
| TS35+TP100Datasheet(opens in a new tab) | 10 mW - 35 W | 0.19-25 μm | 22 mm |
| TS50+TP100Datasheet(opens in a new tab) | 10 mW - 50 W | 0.19-25 μm | 22 mm |
| TS100+TP100Datasheet(opens in a new tab) | 0.5 W - 100 W | 0.19-25 μm | 25 mm |
| TS100-40+TP100Datasheet(opens in a new tab) | 0.5 W - 100 W | 0.19-25 μm | 40 mm |
| TS200+TP100Datasheet(opens in a new tab) | 0.5 W - 200 W | 0.19-25 μm | 25 mm |
| TS300+TP100Datasheet(opens in a new tab) | 0.5 W - 300 W | 0.19-25 μm | 25 mm |
| TS700+TP100Datasheet(opens in a new tab) | 1 W - 700 W | 0.19-20 μm | 55 mm |
HS sensitive thermopile power meters
| Model and datasheet | Optical power range | Wavelength range | Active area |
|---|---|---|---|
| HS1+TP100Datasheet(opens in a new tab) | 100 μW - 1 W | 0.19-20 μm | 9 mm |
| HS5+TP100Datasheet(opens in a new tab) | 100 μW - 5 W | 0.19-20 μm | 9 mm |
Handheld power meters
| Model and datasheet | Optical power range | Wavelength range | Active area |
|---|---|---|---|
| HP2Datasheet(opens in a new tab) | 10 mW - 2 W | 0.19-25 μm | 25 mm |
| HP50Datasheet(opens in a new tab) | 0.5 W - 50 W | 0.19-25 μm | 25 mm |
Photodiode power meters
| Model and datasheet | Optical power range | Wavelength range | Active area |
|---|---|---|---|
| PD100-350+TP100Datasheet(opens in a new tab) | 1 nW - 100 mW | 350-1100 nm | 9.5 mm |
| PD1000-350+TP100Datasheet(opens in a new tab) | 1 nW - 1000 mW | 350-1100 nm | 9.5 mm |
| PD100-350T+TP100Datasheet(opens in a new tab) | 1 nW - 100 mW | 350-1100 nm | 10 × 10 mm |
| PD1000-350T+TP100Datasheet(opens in a new tab) | 1 nW - 1000 mW | 350-1100 nm | 10 × 10 mm |
| PD20-200+TP100Datasheet(opens in a new tab) | 1 nW - 20 mW | 200-1100 nm | 9.5 mm |
| PD1000-200+TP100Datasheet(opens in a new tab) | 1 nW - 1000 mW | 200-1100 nm | 9.5 mm |
| PD20-200T+TP100Datasheet(opens in a new tab) | 1 nW - 20 mW | 200-1100 nm | 10 × 10 mm |
| PD1000-200T+TP100Datasheet(opens in a new tab) | 1 nW - 1000 mW | 200-1100 nm | 10 × 10 mm |
| PD10-800-TP100Datasheet(opens in a new tab) | 1 μW - 10 mW | 800-1800 nm | 9.5 mm |
| PD1000-800-TP100Datasheet(opens in a new tab) | 1 μW - 1000 mW | 800-1800 nm | 9.5 mm |
Integrating-sphere power meters
| Model and datasheet | Optical power range | Wavelength range | Active area |
|---|---|---|---|
| PD3000-350+TP100Datasheet(opens in a new tab) | 1 μW - 3000 mW | 350-1100 nm | 12 mm |
| PD5000-350+TP100Datasheet(opens in a new tab) | 1 μW - 5000 mW | 350-1100 nm | 12 mm |
USB power meters
Need this configured?
Share wavelength range, measurement target, detector needs, sample geometry, software and interface requirements, and we will qualify the matching configuration.