Back to Home
Terug naar cryogene piëzotafels

Alle Zolix-catalogusregels

Volledige catalogus cryogene piëzotafels

Elke bruikbare cryogene tafel, scanner, Ultra-omgevingsvariant, controller, adapterplaat, thermische verbinding en toolkit staat hier vermeld, met specificatietoelichting per model.

73 catalogusregels beschikbaar voor aanvraag.

73 van 73 catalogusregels weergegeven.

GroepModel / familieSpecificatiesAanvraag
Adapter plates - interconnectAP.LT.L16x
Pure titanium interconnect adapter plate for mounting Linear16-x onto other MultiFields LT cryogenic positioners; non-magnetic screws included.
Adapter plates - interconnectAP.LT.L16z
Pure titanium interconnect adapter plate for mounting Linear16-z onto other MultiFields LT cryogenic positioners; non-magnetic screws included.
Adapter plates - interconnectAP.LT.L25
Pure titanium interconnect adapter plate used for Scanner16 and 25 mm class LT positioner cross-mounting; non-magnetic screws included.
Adapter plates - interconnectAP.LT.R16
Pure titanium interconnect adapter plate for mounting Rotator16 onto other MultiFields LT cryogenic positioners; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.G25-v
Pure titanium vertical-orientation adapter plate for tilting Goniometer25 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.G35-v
Pure titanium vertical-orientation adapter plate for tilting Goniometer35 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.L16x-v
Pure titanium vertical-orientation adapter plate for tilting Linear16-x by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.L16z-v
Pure titanium vertical-orientation adapter plate for tilting Linear16-z by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.L25-v
Pure titanium vertical-orientation adapter plate for tilting Linear25 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.L35-v
Pure titanium vertical-orientation adapter plate for tilting Linear35 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.R16-v
Pure titanium vertical-orientation adapter plate for tilting Rotator16 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.R25-v
Pure titanium vertical-orientation adapter plate for tilting Rotator25 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.R25.Optic-v
Pure titanium vertical-orientation adapter plate for tilting Rotator25-Optic by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.R35-v
Pure titanium vertical-orientation adapter plate for tilting Rotator35 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Closed-loop Ultra scannersScanner25-x.Ultra
Closed-loop Ultra X-axis scanner; 25 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; standard cryogenic environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-x.Ultra.HV
Closed-loop Ultra X-axis scanner; 25 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; high-vacuum HV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-x.Ultra.UHV
Closed-loop Ultra X-axis scanner; 25 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; ultra-high-vacuum UHV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-x.Ultra.UHV.ULT
Closed-loop Ultra X-axis scanner; 25 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; combined UHV plus ultra-low-temperature grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-x.Ultra.ULT
Closed-loop Ultra X-axis scanner; 25 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; ultra-low-temperature ULT grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-z.Ultra
Closed-loop Ultra Z-axis scanner; 25 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; standard cryogenic environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-z.Ultra.HV
Closed-loop Ultra Z-axis scanner; 25 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; high-vacuum HV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-z.Ultra.UHV
Closed-loop Ultra Z-axis scanner; 25 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; ultra-high-vacuum UHV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-z.Ultra.UHV.ULT
Closed-loop Ultra Z-axis scanner; 25 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; combined UHV plus ultra-low-temperature grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-z.Ultra.ULT
Closed-loop Ultra Z-axis scanner; 25 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; ultra-low-temperature ULT grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-xy.Ultra
Closed-loop Ultra XY scanner; 35 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; standard cryogenic environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-xy.Ultra.HV
Closed-loop Ultra XY scanner; 35 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; high-vacuum HV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-xy.Ultra.UHV
Closed-loop Ultra XY scanner; 35 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; ultra-high-vacuum UHV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-xy.Ultra.UHV.ULT
Closed-loop Ultra XY scanner; 35 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; combined UHV plus ultra-low-temperature grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-xy.Ultra.ULT
Closed-loop Ultra XY scanner; 35 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; ultra-low-temperature ULT grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-z.Ultra
Closed-loop Ultra Z-axis scanner; 35 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; standard cryogenic environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-z.Ultra.HV
Closed-loop Ultra Z-axis scanner; 35 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; high-vacuum HV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-z.Ultra.UHV
Closed-loop Ultra Z-axis scanner; 35 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; ultra-high-vacuum UHV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-z.Ultra.UHV.ULT
Closed-loop Ultra Z-axis scanner; 35 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; combined UHV plus ultra-low-temperature grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-z.Ultra.ULT
Closed-loop Ultra Z-axis scanner; 35 mm cryogenic scanner profile; integrated high-linearity capacitive displacement sensors with sub-nanometer resolution class; ultra-low-temperature ULT grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
ControllersMC-ArchimedesLT.03
Three-channel open-loop cryogenic scanner controller; ultra-low-noise analog outputs; SPI digital synchronization for Scanner16/25/35 flexure scanners.
ControllersMC-ArchimedesLT.03.Ultra
Closed-loop Ultra scanner controller; three drive channels plus capacitive feedback loops; 50 kSa/s realtime loop; EtherCAT, Ethernet, and USB 3.0 interfaces.
ControllersMC-NewtonLT.01
One-channel cryogenic positioner controller; coarse stick-slip drive plus fine analog output; USB and SDK interfaces for Linear, Rotator, Goniometer, and LS-Linear stages.
ControllersMC-NewtonLT.06
Six-channel cryogenic positioner controller; independent multi-axis drive for stacked cryogenic positioners and long-stroke assemblies.
GoniometersGoniometer25-phi
Cryogenic phi goniometer; 25 x 25 mm footprint; 6.0 deg tilt range; 53.5 mm pivot distance above plate; 200 g payload; resistive closed-loop feedback around 0.2-0.5 mdeg resolution.
GoniometersGoniometer25-theta
Cryogenic theta goniometer; 25 x 25 mm footprint; 6.6 deg tilt range; 41 mm pivot distance above plate; 200 g payload; resistive closed-loop feedback around 0.2-0.5 mdeg resolution.
GoniometersGoniometer35-phi
Cryogenic phi goniometer; 35 x 35 mm footprint; 10.0 deg tilt range; 66 mm pivot distance above plate; 500 g payload; resistive closed-loop feedback around 0.2-0.5 mdeg resolution.
GoniometersGoniometer35-theta
Cryogenic theta goniometer; 35 x 35 mm footprint; 12.0 deg tilt range; 50 mm pivot distance above plate; 500 g payload; resistive closed-loop feedback around 0.2-0.5 mdeg resolution.
Installation platesAP.LT.InstPlate
Installation plate for direct optical-table mounting of MultiFields LT cryogenic positioners; use where a fixed base interface is required.
Installation platesAP.LT.PinsPlate
Pin-aligned installation plate for directly mounting most MultiFields LT motion units to an optical table or base plate; supplied as the cryogenic PinsPlate adapter.
Linear positionersLinear16-x
Compact cryogenic X linear stage; 16 x 16 x 10.5 mm body; 3 mm coarse travel; 50 g payload; pure titanium construction; optional resistive closed-loop encoder around 150 nm resolution.
Linear positionersLinear16-z
Compact cryogenic Z elevation stage; 16 x 16 x 10.5 mm body; 3 mm coarse travel; 250 g payload; spring-counterbalanced Z mechanics; optional resistive closed-loop encoder around 150 nm resolution.
Linear positionersLinear25-x
General-purpose cryogenic X linear stage; 25 x 25 x 9.5 mm body; 6 mm coarse travel; 500 g payload; optional resistive closed-loop encoder around 150 nm resolution.
Linear positionersLinear25-z
General-purpose cryogenic Z elevation stage; 25 x 25 x 9.5 mm body; 6 mm coarse travel; 300 g payload; optional resistive closed-loop encoder around 150 nm resolution.
Linear positionersLinear25-z.LR
Long-range cryogenic Z elevation stage in the Linear25 profile; 25 mm class body; extended Z travel configuration; compatible with resistive closed-loop feedback.
Linear positionersLinear35-x
High-load cryogenic X linear stage; 35 x 35 x 10.5 mm body; 20 mm coarse travel; 2.5 kg payload; supports resistive or Linear35 optical encoder feedback.
Linear positionersLinear35-z-Optic
Cryogenic Z optic elevation stage; 35 x 35 x 10.5 mm body; 8 mm Z travel; 500 g payload; optical aperture support; compatible with Linear35 optical encoder feedback.
Long-stroke linearLS-Linear100
Long-stroke cryogenic linear stage; 100 mm travel; 180 x 32 x 19.5 mm footprint; 1 kg payload; full-travel resistive closed-loop encoder with 150 nm sensor resolution.
Long-stroke linearLS-Linear200
Long-stroke cryogenic linear stage; 200 mm travel; 320 x 32 x 19.5 mm footprint; 1.5 kg payload; full-travel resistive closed-loop encoder with 150 nm sensor resolution.
Long-stroke linearLS-Linear30
Long-stroke cryogenic linear stage; 30 mm travel; 60 x 32 x 19.5 mm footprint; 750 g payload; full-travel resistive closed-loop encoder with 150 nm sensor resolution.
Long-stroke linearLS-Linear50
Long-stroke cryogenic linear stage; 50 mm travel; 90 x 32 x 19.5 mm footprint; 750 g payload; full-travel resistive closed-loop encoder with 150 nm sensor resolution.
Long-stroke linearLS-Linear75
Long-stroke cryogenic linear stage; 75 mm travel; 135 x 32 x 19.5 mm footprint; 1 kg payload; full-travel resistive closed-loop encoder with 150 nm sensor resolution.
Open-loop scannersScanner16-xy
Open-loop cryogenic XY flexure scanner; 30 x 30 um range at 300 K or 12 x 12 um at 4 K; friction-free flexure body; sub-nanometer positioning class; 75 V @300 K / 180 V @4 K drive range.
Open-loop scannersScanner16-z
Open-loop cryogenic Z flexure scanner; 10 um range at 300 K or 6 um at 4 K; friction-free flexure body; sub-nanometer positioning class; 75 V @300 K / 180 V @4 K drive range.
Open-loop scannersScanner25-xy
Open-loop cryogenic XY flexure scanner; 55 x 55 um range at 300 K or 24 x 24 um at 4 K; friction-free flexure body; sub-nanometer positioning class; 75 V @300 K / 180 V @4 K drive range.
Open-loop scannersScanner25-z
Open-loop cryogenic Z flexure scanner; 20 um range at 300 K or 12 um at 4 K; friction-free flexure body; sub-nanometer positioning class; 75 V @300 K / 180 V @4 K drive range.
Open-loop scannersScanner35-xy
Open-loop cryogenic XY flexure scanner; 100 x 100 um range at 300 K or 60 x 60 um at 4 K; friction-free flexure body; sub-nanometer positioning class; 75 V @300 K / 180 V @4 K drive range.
Open-loop scannersScanner35-xy-Optic
Open-loop cryogenic XY optic scanner; 35 mm class flexure body; integrated optical clear-aperture path; sub-nanometer positioning class; 75 V @300 K / 180 V @4 K drive range.
Open-loop scannersScanner35-z
Open-loop cryogenic Z flexure scanner; 60 um range at 300 K or 36 um at 4 K; friction-free flexure body; sub-nanometer positioning class; 75 V @300 K / 180 V @4 K drive range.
Open-loop scannersScanner35-z-Optic
Open-loop cryogenic Z optic scanner; 35 mm class flexure body; integrated optical clear-aperture path; sub-nanometer positioning class; 75 V @300 K / 180 V @4 K drive range.
RotatorsRotator16
Compact cryogenic rotary stage; 16 mm profile; 360 deg endless rotation; 100 g payload; 5 microdeg fine-step resolution.
RotatorsRotator25
General-purpose cryogenic rotary stage; 25 x 25 x 16.5 mm body; 360 deg endless rotation; 250 g payload; 4 microdeg fine-step resolution.
RotatorsRotator25-Optic
Cryogenic rotary optic stage; 25 x 25 x 16.5 mm body; 6 mm center aperture; 360 deg endless rotation; 250 g payload.
RotatorsRotator35
High-load cryogenic rotary stage; 35 x 35 x 16.5 mm body; 360 deg endless rotation; 500 g payload; 3 microdeg fine-step resolution.
RotatorsRotator35-Optic
High-load cryogenic rotary optic stage; 35 x 35 x 16.5 mm body; 6 mm center aperture; 360 deg endless rotation; 500 g payload.
Thermal linksFTC16.L**
Flexible thermal connection set for 16 mm Linear and Scanner series stacks; 30 mK to 420 K, ambient/HV/UHV compatible, usable up to 35 T; choose 35, 65, or 100 mm copper coupling foil length.
Thermal linksFTC25.L**
Flexible thermal connection set for 25 mm Linear and Scanner series stacks; 30 mK to 420 K, ambient/HV/UHV compatible, usable up to 35 T; choose 35, 65, or 100 mm copper coupling foil length.
Thermal linksFTC35.L**
Flexible thermal connection set for 35 mm Linear, Goniometer, and Scanner series stacks; 30 mK to 420 K, ambient/HV/UHV compatible, usable up to 35 T; choose 35, 65, or 100 mm copper coupling foil length.
ToolkitsPM.LT.ToolBox.Basic
Basic cryogenic installation toolbox; one set with BeCu M1.6/M2 screws, PA-standard 2/3/4-pin connectors, Peek UHV 4-pin connector parts, screwdriver, tweezers, USB driver, software, and manual.