GroepModel / familieSpecificatiesAanvraag
Adapter plates - interconnectAP.LT.L16x
Pure titanium interconnect adapter plate for mounting Linear16-x onto other MultiFields LT cryogenic positioners; non-magnetic screws included.
Adapter plates - interconnectAP.LT.L16z
Pure titanium interconnect adapter plate for mounting Linear16-z onto other MultiFields LT cryogenic positioners; non-magnetic screws included.
Adapter plates - interconnectAP.LT.L25
Pure titanium interconnect adapter plate used for Scanner16 and 25 mm class LT positioner cross-mounting; non-magnetic screws included.
Adapter plates - interconnectAP.LT.R16
Pure titanium interconnect adapter plate for mounting Rotator16 onto other MultiFields LT cryogenic positioners; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.G25-v
Pure titanium vertical-orientation adapter plate for tilting Goniometer25 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.G35-v
Pure titanium vertical-orientation adapter plate for tilting Goniometer35 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.L16x-v
Pure titanium vertical-orientation adapter plate for tilting Linear16-x by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.L16z-v
Pure titanium vertical-orientation adapter plate for tilting Linear16-z by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.L25-v
Pure titanium vertical-orientation adapter plate for tilting Linear25 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.L35-v
Pure titanium vertical-orientation adapter plate for tilting Linear35 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.R16-v
Pure titanium vertical-orientation adapter plate for tilting Rotator16 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.R25-v
Pure titanium vertical-orientation adapter plate for tilting Rotator25 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.R25.Optic-v
Pure titanium vertical-orientation adapter plate for tilting Rotator25-Optic by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Adapter plates - vertical orientationAP.LT.R35-v
Pure titanium vertical-orientation adapter plate for tilting Rotator35 by 90 deg in MultiFields LT cryogenic stacks; non-magnetic screws included.
Closed-loop Ultra scannersScanner25-x.Ultra
Closed-loop Ultra X-axis scanner; 25 x 25 x 10.5 mm body; 55 um range per axis at 300 K, 30 um at 4 K; 250 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; standard cryogenic environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-x.Ultra.HV
Closed-loop Ultra X-axis scanner; 25 x 25 x 10.5 mm body; 55 um range per axis at 300 K, 30 um at 4 K; 250 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; high-vacuum HV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-x.Ultra.UHV
Closed-loop Ultra X-axis scanner; 25 x 25 x 10.5 mm body; 55 um range per axis at 300 K, 30 um at 4 K; 250 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; ultra-high-vacuum UHV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-x.Ultra.UHV.ULT
Closed-loop Ultra X-axis scanner; 25 x 25 x 10.5 mm body; 55 um range per axis at 300 K, 30 um at 4 K; 250 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; combined UHV plus ultra-low-temperature grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-x.Ultra.ULT
Closed-loop Ultra X-axis scanner; 25 x 25 x 10.5 mm body; 55 um range per axis at 300 K, 30 um at 4 K; 250 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; ultra-low-temperature ULT grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-z.Ultra
Closed-loop Ultra Z-axis scanner; 25 x 25 x 10.5 mm body; 55 um range per axis at 300 K, 30 um at 4 K; 250 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; standard cryogenic environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-z.Ultra.HV
Closed-loop Ultra Z-axis scanner; 25 x 25 x 10.5 mm body; 55 um range per axis at 300 K, 30 um at 4 K; 250 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; high-vacuum HV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-z.Ultra.UHV
Closed-loop Ultra Z-axis scanner; 25 x 25 x 10.5 mm body; 55 um range per axis at 300 K, 30 um at 4 K; 250 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; ultra-high-vacuum UHV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-z.Ultra.UHV.ULT
Closed-loop Ultra Z-axis scanner; 25 x 25 x 10.5 mm body; 55 um range per axis at 300 K, 30 um at 4 K; 250 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; combined UHV plus ultra-low-temperature grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner25-z.Ultra.ULT
Closed-loop Ultra Z-axis scanner; 25 x 25 x 10.5 mm body; 55 um range per axis at 300 K, 30 um at 4 K; 250 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; ultra-low-temperature ULT grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-xy.Ultra
Closed-loop Ultra XY scanner; 35 x 35 x 14.5 mm body; 100 um range per axis at 300 K, 60 um at 4 K; 500 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; standard cryogenic environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-xy.Ultra.HV
Closed-loop Ultra XY scanner; 35 x 35 x 14.5 mm body; 100 um range per axis at 300 K, 60 um at 4 K; 500 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; high-vacuum HV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-xy.Ultra.UHV
Closed-loop Ultra XY scanner; 35 x 35 x 14.5 mm body; 100 um range per axis at 300 K, 60 um at 4 K; 500 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; ultra-high-vacuum UHV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-xy.Ultra.UHV.ULT
Closed-loop Ultra XY scanner; 35 x 35 x 14.5 mm body; 100 um range per axis at 300 K, 60 um at 4 K; 500 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; combined UHV plus ultra-low-temperature grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-xy.Ultra.ULT
Closed-loop Ultra XY scanner; 35 x 35 x 14.5 mm body; 100 um range per axis at 300 K, 60 um at 4 K; 500 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; ultra-low-temperature ULT grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-z.Ultra
Closed-loop Ultra Z-axis scanner; 35 x 35 x 14.5 mm body; 100 um range per axis at 300 K, 60 um at 4 K; 500 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; standard cryogenic environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-z.Ultra.HV
Closed-loop Ultra Z-axis scanner; 35 x 35 x 14.5 mm body; 100 um range per axis at 300 K, 60 um at 4 K; 500 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; high-vacuum HV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-z.Ultra.UHV
Closed-loop Ultra Z-axis scanner; 35 x 35 x 14.5 mm body; 100 um range per axis at 300 K, 60 um at 4 K; 500 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; ultra-high-vacuum UHV environment grade; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-z.Ultra.UHV.ULT
Closed-loop Ultra Z-axis scanner; 35 x 35 x 14.5 mm body; 100 um range per axis at 300 K, 60 um at 4 K; 500 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; combined UHV plus ultra-low-temperature grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
Closed-loop Ultra scannersScanner35-z.Ultra.ULT
Closed-loop Ultra Z-axis scanner; 35 x 35 x 14.5 mm body; 100 um range per axis at 300 K, 60 um at 4 K; 500 g payload; integrated capacitive displacement sensor, 0.5 nm resolution, ~0.1 % linearity, <5 nm repeatability; max. 75 V @300 K / 150 V @4 K; ultra-low-temperature ULT grade down to 30 mK; use with MC-ArchimedesLT.03.Ultra controller.
ControllersMC-ArchimedesLT.03
Three-channel open-loop cryogenic scanner controller; ultra-low-noise analog outputs; SPI digital synchronization for Scanner16/25/35 flexure scanners.
ControllersMC-ArchimedesLT.03.Ultra
Closed-loop Ultra scanner controller; three drive channels plus capacitive feedback loops; 50 kSa/s realtime loop; EtherCAT, Ethernet, and USB 3.0 interfaces.
ControllersMC-NewtonLT.01
One-channel cryogenic positioner controller; coarse stick-slip drive plus fine analog output; USB and SDK interfaces for Linear, Rotator, Goniometer, and LS-Linear stages.
ControllersMC-NewtonLT.06
Six-channel cryogenic positioner controller; independent multi-axis drive for stacked cryogenic positioners and long-stroke assemblies.
Cryogenic Linear Piezo StagesLinear16-x.HV
Linear16-x.HV — Cryogenic Linear Piezo Stages.
Cryogenic Linear Piezo StagesLinear25-x.HV
Linear25-x.HV — Cryogenic Linear Piezo Stages.
Cryogenic Linear Piezo StagesLinear35-x.HV
Linear35-x.HV — Cryogenic Linear Piezo Stages.
Cryogenic Rotary Piezo StagesRotator16.HV
Rotator16.HV — Cryogenic Rotary Piezo Stages.
Cryogenic Rotary Piezo StagesRotator25-optic.HV
Rotator25-optic.HV — Cryogenic Rotary Piezo Stages.
Cryogenic Rotary Piezo StagesRotator25.HV
Rotator25.HV — Cryogenic Rotary Piezo Stages.
Cryogenic Rotary Piezo StagesRotator35.HV
Rotator35.HV — Cryogenic Rotary Piezo Stages.
Cryogenic ScannersScanner16-xy.HV
Scanner16-xy.HV — Cryogenic Scanners.
Cryogenic ScannersScanner16-z.HV
Scanner16-z.HV — Cryogenic Scanners.
Cryogenic ScannersScanner25-xy.HV
Scanner25-xy.HV — Cryogenic Scanners.
Cryogenic ScannersScanner25-z.HV
Scanner25-z.HV — Cryogenic Scanners.
Cryogenic ScannersScanner35-xy.HV
Scanner35-xy.HV — Cryogenic Scanners.
Cryogenic ScannersScanner35-z.HV
Scanner35-z.HV — Cryogenic Scanners.
Cryogenic Tip/Tilt Piezo StagesGoniometer25-phi.HV
Goniometer25-phi.HV — Cryogenic Tip/Tilt Piezo Stages.
Cryogenic Tip/Tilt Piezo StagesGoniometer25-theta.HV
Goniometer25-theta.HV — Cryogenic Tip/Tilt Piezo Stages.
Cryogenic Tip/Tilt Piezo StagesGoniometer35-phi.HV
Goniometer35-phi.HV — Cryogenic Tip/Tilt Piezo Stages.
Cryogenic Tip/Tilt Piezo StagesGoniometer35-theta.HV
Goniometer35-theta.HV — Cryogenic Tip/Tilt Piezo Stages.
Cryogenic Vertical Piezo StagesLinear16-z.HV
Linear16-z.HV — Cryogenic Vertical Piezo Stages.
Cryogenic Vertical Piezo StagesLinear25-z.HV
Linear25-z.HV — Cryogenic Vertical Piezo Stages.
Cryogenic Vertical Piezo StagesLinear25-z.LR.HV
Linear25-z.LR.HV — Cryogenic Vertical Piezo Stages.
Cryogenic Vertical Piezo StagesLinear35-z.HV
Linear35-z.HV — Cryogenic Vertical Piezo Stages.
GoniometersGoniometer25-phi
Cryogenic phi goniometer; 25 x 25 mm footprint; 6.0 deg tilt range; 53.5 mm pivot distance above plate; 200 g payload; resistive closed-loop feedback around 0.2-0.5 mdeg resolution.