Server-rendered product directory
Fibre-Optic Spectrometers model catalog
Browse 21 canonical product destinations across 21 product families. Page 1 lists models 1–21.
- Accessory — Collection opticsOptical signal collectorOptical Signal Collector L-UV / L-VISA 5 mm, 6 mm focal-length collection lens that screws onto the fibre to gather light from a source or sample. The L-UV version transmits from 200 nm, the L-VIS from 350 nm.View product →
- Accessory — FibresOptical fibresSMA905 Optical Fibres for SpectrometersSingle-strand multimode fibres with SMA905 connectors to carry light from the sample or source to the spectrometer entrance. Other core diameters and lengths on request.View product →
- Accessory — FiltersRaman spectroscopy filtersRaman Spectroscopy Filter Sets for 532 nm and 785 nmIon-beam-sputtered laser clean-up, ultra-steep long-pass edge and laser dichroic filters for 532 nm and 785 nm Raman: high optical density at the laser line, high transmission of the Raman-shifted light, and edges steep enough to reach low wavenumbers.View product →
- Accessory — GratingsPlane ruled gratingsPlane Ruled Diffraction GratingsReflective plane ruled gratings from 600 to 3600 lines/mm, blazed between 200 nm and 1000 nm, with 60–80 % efficiency at the blaze wavelength — the dispersive element for spectrometers, monochromators, spectrophotometers and biochemical instruments.View product →
- Accessory — HoldersFibre holdersFibre and Collimator Holders FH-01 to FH-04Bench stands that hold a fibre or fibre collimator over the sample at an adjustable angle and height — a round or square base for petri dishes, a post-mounted collimator holder, a tall column, and a compact holder for the FOC-01 collimators.View product →
- Accessory — Light sourceHLS-1000HLS-1000 Halogen-Tungsten Light SourceA fan-cooled 2800 K halogen-tungsten source with a continuous 340–2000 nm spectrum, an SMA905 output and a filter slot at the exit port. Paired with a spectrometer and a cuvette holder or reflection probe it forms an absorbance, transmittance or reflectivity measurement system.View product →
- Accessory — Order-sorting filterLinear variable long-pass filterLinear Variable Long-Wave-Pass FilterAn ion-sputtered quartz filter whose long-wave-pass cut-off shifts continuously along its length. Mounted in front of the detector of a fibre spectrometer it blocks the higher diffraction orders of the grating across the whole spectrum at once.View product →
- Accessory — Sample holdersCuvette holdersFour-Way, Raman and Adjustable Cuvette HoldersHolders for standard 10 × 10 mm cuvettes. The four-way holder has SMA905 ports on all four sides for absorption, transmission, reflection and fluorescence; the Raman and adjustable holders connect a Raman/fluorescence probe to solid or liquid samples, the adjustable version with fine control of the sample distance.View product →
- Accessory — SynchronisationEX-TA / EX-TB trigger boxesTG-Series External Trigger Boxes EX-TA and EX-TBTrigger boxes for the TG (external-triggering) versions of the Aurora 4000 and Sunshine. The EX-TA exposes every spectrometer parameter to the software through the 30-pin connector; the EX-TB adds an independent signal source that fans out two synchronous trigger signals with software-set delay in 5 ns steps.View product →
- Probe — Fluorescence probesFPB fluorescence probesFPB Series Fibre-Coupled Fluorescence Probes, 405–980 nmThe same solidified probe bodies as the Raman range, with the filter set chosen for fluorescence: the laser line is blocked and the emission band passed to the spectrometer. Nine excitation wavelengths from 405 to 980 nm, the last two covering up-conversion emission from rare-earth phosphors.View product →
- Probe — Raman probe with cameraImaging Raman probeIRPB Imaging Raman Probe with Built-In CameraA standard Raman probe combined with an imaging path and a USB colour camera, so the laser spot is seen on the sample while it is positioned. 532 nm or 785 nm excitation, 150–4500 cm⁻¹, a 2 × 1.5 mm field of view at 1280 × 1024 pixels.View product →
- Probe — Raman probe, two excitation linesRPB-532/785 dual probeRPB-532/785 Dual-Wavelength Raman ProbeOne probe body with two complete excitation and collection paths — four fibres in all — so a sample can be measured at 532 nm and at 785 nm without moving it or swapping probes. Both lines cover 150–4500 cm⁻¹.View product →
- Probe — Raman probesRPB Raman probesRPB Series Fibre-Coupled Raman Probes, 360–1064 nmFully solidified (cured) optical probes that carry the excitation laser to the sample and collect the Raman return into a fibre spectrometer, at twelve excitation wavelengths from 360 to 1064 nm. Three body styles share the same 7.5 mm focal length; the -L versions at 532, 639, 785, 830 and 1064 nm reach 100 cm⁻¹.View product →
- Spectrometer — CompactFirefly 4000Firefly 4000 Compact Fibre-Optic SpectrometerThe same 3648-pixel linear CCD as the Aurora 4000 in a 170 g housing that fits in a hand. The spectral window is limited to a 650 nm span within 200–1100 nm, with 1.0 nm resolution or better.View product →
- Spectrometer — High resolutionAurora 4000Aurora 4000 High-Resolution Fibre-Optic SpectrometerA 3648-pixel linear-CCD spectrometer on a 101.6 mm crossed Czerny-Turner bench. With a narrow grating range and a 10 µm entrance aperture it resolves 0.08 nm; the standard 200–1100 nm configuration gives 0.75 nm. Wavelength range and resolution are configured to order.View product →
- Spectrometer — High sensitivitySunshineSunshine High-Sensitivity Fibre-Optic SpectrometerA 2048-pixel spectrometer with 14 µm square pixels and up to 80 % quantum efficiency, for weak signals — Raman, fluorescence and LIBS — where the Aurora’s narrow 8 µm pixels would starve. Raman-specific ranges are available for 532 nm and 785 nm excitation.View product →
- Spectrometer — Multi-channel, synchronisedRainbow multi-channelRainbow Series Multi-Channel SpectrometerTwo to six Aurora-class 3648-pixel spectrometers in one housing, each covering a slice of the spectrum, with a synchronous delay device that fires all channels together. Wide range and high resolution at once — 185–930 nm at 0.08–0.22 nm in the standard configurations — with internal or external triggering for pulsed sources.View product →
- Spectrometer — Near-infrared, InGaAsWoodWood Near-Infrared Fibre-Optic SpectrometerA near-infrared spectrometer built around a two-stage cooled 256-pixel InGaAs array, in 900–1700 nm or 1000–2500 nm versions. Sub-millisecond integration and a 1200:1 signal-to-noise ratio suit on-line monitoring in industrial and agricultural settings.View product →
- Spectrometer — TE-cooled, back-illuminated CCDMetalMetal TE-Cooled Fibre-Optic SpectrometerA thermoelectrically cooled spectrometer with a Hamamatsu back-illuminated area-array CCD. Cooling 20 °C below ambient lowers the dark current enough for 60 s integrations, so weak Raman and fluorescence signals build up without the noise floor rising with them.View product →
- System — Application system, jewelleryDiamond identification RamanRaman Spectrometer Solution for Diamond and Gem IdentificationA complete Raman solution configured for gem laboratories: a narrow-linewidth fibre-coupled laser, a high-sensitivity Sunshine spectrometer, a Raman probe on an adjustable holder, a computer and identification software. Natural diamond shows a single sharp line at 1332 cm⁻¹; synthetic material and imitations show additional bands, so authenticity is settled in a single measurement.View product →
- System — Benchtop, probe-basedT-RamanSys desktop RamanT-RamanSys Desktop Raman Spectrometer System, 405 / 532 / 785 / 830 nmA benchtop Raman spectrometer in one 420 × 272 × 160 mm enclosure: a frequency-stabilised fibre-coupled laser, a Sunshine TG-Raman fibre spectrometer and the Raman Analysis software with library matching, with an RPB Raman probe connected externally. Four excitation lines — 405, 532, 785 and 830 nm — each with its own spectrometer range and resolution.View product →