We provide cost-effective fiber-coupled laser sources with a wide range emitting spectrum from 370nm to 2000nm and line width from 10kHz to broadband to select. Each benchtop laser source features a pigtailed laser and high-precision, low-noise auto-feedback drive electronics to ensure constant output power or a constant driving current, and an integrated temperature control unit maintains optimal operating conditions. Each unit features a front fiber output connector and a universal power supply compatible with 100 to 240 VAC. We offer two packages: benchtop for ease of use and compact module for system integration. The user interface benchtop includes an intuitive LCD display for independent control of output power and temperature via two front rotating knobs. The module has two front output power and temperature settings.

395-405nm Fiber Coupled FP Laser Source

Configuration options

Build & quote

Configure the options below and add your exact build to the enquiry — we confirm the part number and availability.

We confirm the exact part number for your configuration on enquiry.

Wavelength: 400nm · Power: 15mW · Linewidth: 2nm · Package: Benchtop · Isolator: None · Control Mode: Constant Current · TEC Cooling: No · Fiber Type: SM400 · Connector: Non

Application context

Why this design is used

Application guidance is tied to the configured wavelength, fiber interface and optical-budget fields for this family.

Laboratory optical integration

395-405nm Fiber Coupled FP Laser Source: Laboratory optical integration depends on preserving the optical budget through the complete path. The 400nm wavelength specification sets source and detector compatibility. The fiber/interface entry (SM400, PM400) must match the connected components.

Fiber-optic instrumentation

395-405nm Fiber Coupled FP Laser Source: Fiber-optic instrumentation depends on preserving the optical budget through the complete path. The 400nm wavelength specification sets source and detector compatibility. The fiber/interface entry (SM400, PM400) must match the connected components.

Downloads

Datasheets & documents

System integration

Integration and compatibility

Use these checks to connect 395-405nm Fiber Coupled FP Laser Source to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Optical interface and fiber
Fiber Type: SM400, PM400 · Connector: Non, FC/APC, FC/PC, Special
Specify connector polish and fiber architecture together. FC/PC, FC/APC and SMA interfaces, and single-mode, multimode and polarization-maintaining fibers, impose different return-loss, mode-field and alignment requirements.
Wavelength and loss budget
Wavelength: 400nm
Check the Laser Diodes & Sources passband, insertion loss, return loss and power handling at the actual source wavelength; a nominal telecom-band label is not a substitute for the configured range.
Control interface
Control Mode: Constant Current, Constant Power
Match supply voltage, analog or digital command range, connector pinout and default optical state to the instrument interlock. Confirm the unpowered state explicitly — it decides what happens to the link on a power failure.

Technical FAQ

Integration questions for 395-405nm Fiber Coupled FP Laser Source

Which fiber and connector does the 395-405nm Fiber Coupled FP Laser Source use?

Fiber Type: SM400, PM400 · Connector: Non, FC/APC, FC/PC, Special. Specify connector polish and fiber architecture together. FC/PC, FC/APC and SMA interfaces, and single-mode, multimode and polarization-maintaining fibers, impose different return-loss, mode-field and alignment requirements.

How should the 395-405nm Fiber Coupled FP Laser Source be included in an optical power budget?

Wavelength: 400nm. Check the Laser Diodes & Sources passband, insertion loss, return loss and power handling at the actual source wavelength; a nominal telecom-band label is not a substitute for the configured range.

Does the 395-405nm Fiber Coupled FP Laser Source require a controller?

Control Mode: Constant Current, Constant Power. Match supply voltage, analog or digital command range, connector pinout and default optical state to the instrument interlock. Confirm the unpowered state explicitly — it decides what happens to the link on a power failure.

Need this configured?

Share your wavelength, fiber type, connector, power handling and control requirements and we will qualify the matching configuration and part number.

Model selection

Nearby series comparison

Compare 395-405nm Fiber Coupled FP Laser Source with the closest available models in the Laser Diodes & Sources family. Confirm option-dependent values on the final configuration before ordering.

Selection parameter395-405nm Fiber Coupled FP Laser Source (current)395-405nm Fiber Coupled FP Laser - 15mW405nm Fiber Coupled FP Laser - 70mW
Wavelength range400nm400nm405nm
Optical performanceConfirm for this modelConfirm for this modelConfirm for this model
Fiber typeSM400, PM400SM400, PM400SM400, PM400
Connector / controlConstant Current, Constant PowerNon, FC/APC, FC/PC, SpecialNon, FC/APC, FC/PC, Special