Back to Home

Laser Diodes & Sources

Ultra High PER PM Fiber Coupled Laser Source 1950nm

The PMLS provide 1950nm PM Laser light with high stability in both output power and polarization extinction ratio. These advantageously features are intrinsically achieved by using a randomly polarized fiber laser with a specially made high polarization extinction ratio polarizer. The spectral width can be selected as broadband, and 5nm. The power control has several options: fixed and remotely via RS232/USB. The output fiber is PM1950.

Ultra High PER PM Fiber Coupled Laser Source 1950nm

Configuration options

Build & quote

Configure the options below and add your exact build to the enquiry — we confirm the part number and availability.

Part number: PMLS-1191N1111

Package: Benchtop · Wavelength: 1950nm · Power: 1mW · ER: Non · Spectral Width: Broad · Output Control: Fixed · Fiber: PM1950 · Connector: None

Application context

Why this design is used

Application guidance is tied to the configured wavelength, fiber interface and optical-budget fields for this family.

Laboratory optical integration

Ultra High PER PM Fiber Coupled Laser Source 1950nm: Laboratory optical integration depends on preserving the optical budget through the complete path. The 1950nm, 1850nm, 2000nm, 2200nm wavelength specification sets source and detector compatibility. The fiber/interface entry (PM1950) must match the connected components.

Fiber-optic instrumentation

Ultra High PER PM Fiber Coupled Laser Source 1950nm: Fiber-optic instrumentation depends on preserving the optical budget through the complete path. The 1950nm, 1850nm, 2000nm, 2200nm wavelength specification sets source and detector compatibility. The fiber/interface entry (PM1950) must match the connected components.

Downloads

Datasheets & documents

System integration

Integration and compatibility

Use these checks to connect Ultra High PER PM Fiber Coupled Laser Source 1950nm to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Optical interface and fiber
Fiber: PM1950 · Connector: None, FC/APC, Special
Specify connector polish and fiber architecture together. FC/PC, FC/APC and SMA interfaces, and single-mode, multimode and polarization-maintaining fibers, impose different return-loss, mode-field and alignment requirements.
Wavelength and loss budget
Wavelength: 1950nm, 1850nm, 2000nm, 2200nm · Spectral Width: Broad, 5nm
Check the Laser Diodes & Sources passband, insertion loss, return loss and power handling at the actual source wavelength; a nominal telecom-band label is not a substitute for the configured range.
Control interface
Output Control: Fixed, Adjustable, USB
Match supply voltage, analog or digital command range, connector pinout and default optical state to the instrument interlock. Confirm the unpowered state explicitly — it decides what happens to the link on a power failure.

Technical FAQ

Integration questions for Ultra High PER PM Fiber Coupled Laser Source 1950nm

Which fiber and connector does the Ultra High PER PM Fiber Coupled Laser Source 1950nm use?

Fiber: PM1950 · Connector: None, FC/APC, Special. Specify connector polish and fiber architecture together. FC/PC, FC/APC and SMA interfaces, and single-mode, multimode and polarization-maintaining fibers, impose different return-loss, mode-field and alignment requirements.

How should the Ultra High PER PM Fiber Coupled Laser Source 1950nm be included in an optical power budget?

Wavelength: 1950nm, 1850nm, 2000nm, 2200nm · Spectral Width: Broad, 5nm. Check the Laser Diodes & Sources passband, insertion loss, return loss and power handling at the actual source wavelength; a nominal telecom-band label is not a substitute for the configured range.

Does the Ultra High PER PM Fiber Coupled Laser Source 1950nm require a controller?

Output Control: Fixed, Adjustable, USB. Match supply voltage, analog or digital command range, connector pinout and default optical state to the instrument interlock. Confirm the unpowered state explicitly — it decides what happens to the link on a power failure.

Need this configured?

Share your wavelength, fiber type, connector, power handling and control requirements and we will qualify the matching configuration and part number.

Model selection

Nearby series comparison

Compare Ultra High PER PM Fiber Coupled Laser Source 1950nm with the closest available models in the Laser Diodes & Sources family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterUltra High PER PM Fiber Coupled Laser Source 1950nm (current)Ultra High PER PM Fiber Coupled Laser 1060nmUltrabroad Single Mode Fiber Coupled Laser: 1300-4500nm, Supercontinuum
Wavelength range1950nm, 1850nm, 2000nm, 2200nm1060nmConfirm for this model
Optical performanceConfirm for this modelConfirm for this modelConfirm for this model
Fiber typePM1950PM980Confirm for this model
Connector / controlFixed, Adjustable, USBFixed, Adjustable, USBNon, USB, RS232