Pulse energy, repetition rate, pulse width
EO-266W266 nm deep-UV Q-switched pulsed laser
266 nmEO-266W is a 266 nm Pulsed laser. Used for marking, carving, measure, research. Key specifications: output / average power 3000 mW, pulse energy 60 uJ, repetition rate 10-100 kHz. View specifications, datasheet and enquiry options from Precisometer.
Specifications
EO-266W
21 specification rows
| Output / average power | 3000 mW |
|---|---|
| Pulse energy | 60 uJ |
| Repetition rate | 10-100 kHz |
| Pulse width | <5 ns |
| Operating mode | Actively Q-switched |
| Power stability (rms, 4 hours ± 3°C) | <2%, <1% |
| Transverse mode | TEM00 |
| Beam divergence, full angle (mrad) | <1.5 |
| Polarization ratio | >100:1 Vertical |
| Warm-up time (minutes) | <10 |
| Cooled method | Water cooled |
| Operating temperature (℃) | 15-35 |
| Operating voltage (VDC) | 24V/31.1A |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 266±1 |
| Average power (W) | 3@50kHz |
| Single pulse energy (µJ) | >60@50kHz |
| Rep. rate | 10-100kHz |
| Pulse duration (ns) | <5 |
| Beam diameter at the aperture (1/e2, mm) | ~2 |
| Beam height from base plate (mm) | 150 |
Applications
Uses named on this model’s datasheet.
- Marking
- Carving
- Measure
- Research
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Related pulsed lasers