Back to Home

Pulse energy, repetition rate, pulse width

MPL-Q-266266 nm deep-UV Q-switched pulsed laser

266 nm

MPL-Q-266 is a 266 nm Pulsed laser. Used for uv curing, micro-electronics, cd carving, laser medical treatment. Key specifications: output / average power 1~30 mW, pulse energy 0.1~3 uJ, repetition rate 3-12 kHz. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MPL-Q-266

20 specification rows

Output / average power1~30 mW
Pulse energy0.1~3 uJ
Repetition rate3-12 kHz
Pulse width~1.3 ns
Operating modePassively Q-switched
Power stability (rms, 4 hours, ±3°C)<5%, <3%
Transverse modeNear TEM00
M2<2
Beam diameter at the aperture (mm)~1.0
Polarization ratio>50:1, Horizontal (Vertical optional)
Warm-up time (minutes)<5
Operating temperature (℃)10-35
Power supply (100-240VAC)PSU-Q-FDA/PSU-Q-LED
Expected lifetime (hours)>10000
Wavelength (nm)266±1
Average power (mW)1-30
Single pulse energy (µJ)0.1-3
<2
Beam divergence, full angle (mrad)/
Beam height from base plate (mm)35

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

UV curing

MPL-Q-266: 266 nm emission determines compatible optics, coatings and detectors for UV curing. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

Micro-electronics

MPL-Q-266: 266 nm emission determines compatible optics, coatings and detectors for Micro-electronics. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

CD carving

MPL-Q-266: 266 nm emission determines compatible optics, coatings and detectors for CD carving. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

Laser medical treatment

MPL-Q-266: 266 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MPL-Q-266 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · M2: <2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MPL-Q-266

What cooling does the MPL-Q-266 require?

Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MPL-Q-266 deliver?

Transverse mode: Near TEM00 · M2: <2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MPL-Q-266 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMPL-Q-266 (current)MPL-Q1-266MPL-FN-266
Wavelength266 nm266 nm266 nm
Optical power / pulse energy1~30 mW10 mW1~15 mW
Operating mode / pulse width3-12 kHz1 kHz10 Hz-3 kHz
Beam qualityNear TEM00Near TEM00Near TEM00