Back to Home

Pulse energy, repetition rate, pulse width

MPL-S-266-HP266 nm deep-UV Q-switched pulsed laser

266 nm

MPL-S-266-HP is a 266 nm Pulsed laser. Used for scientific research, laser micromachining, lidar ranging, environmental monitoring. Key specifications: output / average power 6~100 mW, pulse energy 1~80 uJ, repetition rate 10 Hz-100 kHz. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MPL-S-266-HP

13 specification rows

Wavelength266 nm
Output / average power6~100 mW
Pulse energy1~80 uJ
Repetition rate10 Hz-100 kHz
Pulse width~0.4 ns
Operating modePassively Q-switched
Power stability (rms, 4 hours, ±3°C)<5%, <3%
Transverse modeNear TEM00
Beam diameter at the aperture (mm)~1.5
Warm-up time (minutes)<5
Operating temperature (℃)10-35
Power supply (100-240VAC)PSU-S-HP
Expected lifetime (hours)>10000
Beam divergence, full angle (mrad)<1.5

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Scientific research

MPL-S-266-HP: 266 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

Laser micromachining

MPL-S-266-HP: 266 nm emission determines compatible optics, coatings and detectors for Laser micromachining. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

Lidar ranging

MPL-S-266-HP: Lidar ranging depends on how optical energy is delivered to the target; 266 nm emission governs absorption, while the listed temporal parameter (1~80 uJ) governs peak intensity and heat deposition.

Environmental monitoring

MPL-S-266-HP: 266 nm emission determines compatible optics, coatings and detectors for Environmental monitoring. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MPL-S-266-HP to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · Beam diameter at the aperture (mm): ~1.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MPL-S-266-HP

What cooling does the MPL-S-266-HP require?

Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MPL-S-266-HP deliver?

Transverse mode: Near TEM00 · Beam diameter at the aperture (mm): ~1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MPL-S-266-HP with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMPL-S-266-HP (current)MPL-Q-266MPL-Q1-266
Wavelength266 nm266 nm266 nm
Optical power / pulse energy6~100 mW1~30 mW10 mW
Operating mode / pulse width10 Hz-100 kHz3-12 kHz1 kHz
Beam qualityNear TEM00Near TEM00Near TEM00