Back to Home

Pulse energy, repetition rate, pulse width

MPL-S-266-LP266 nm deep-UV Q-switched pulsed laser

266 nm

MPL-S-266-LP is a 266 nm Pulsed laser. Used for scientific research, laser micromaching, laser radar ranging, environment monitoring. Key specifications: output / average power 1~15 mW, pulse energy 1~15 uJ, repetition rate 1 Hz-1 kHz. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MPL-S-266-LP

19 specification rows

Output / average power1~15 mW
Pulse energy1~15 uJ
Repetition rate1 Hz-1 kHz
Pulse width~0.4 ns
Operating modePassively Q-switched
Power stability (rms, 4 hours, ±3°C)<5%, <3%, <2%
Transverse modeNear TEM00
Beam diameter at the aperture (mm)~2.0
Beam divergence, full angle (mrad)<8
Warm-up time (minutes)<5
Operating temperature (℃)10-35
Power supply (100-240VAC)PSU-S-LP
Expected lifetime (hours)>10000
Wavelength (nm)266±1
Average power (mW)~15
Single pulse energy (µJ)~15
Pulse duration (ns)~0.4
Peak power (kW)37.5
Beam height from base plate (mm)27.4

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Scientific research

MPL-S-266-LP: 266 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

Laser micromaching

MPL-S-266-LP: 266 nm emission determines compatible optics, coatings and detectors for Laser micromaching. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

Laser radar ranging

MPL-S-266-LP: 266 nm emission determines compatible optics, coatings and detectors for Laser radar ranging. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

Environment monitoring

MPL-S-266-LP: 266 nm emission determines compatible optics, coatings and detectors for Environment monitoring. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MPL-S-266-LP to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · Beam diameter at the aperture (mm): ~2.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MPL-S-266-LP

What cooling does the MPL-S-266-LP require?

Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MPL-S-266-LP deliver?

Transverse mode: Near TEM00 · Beam diameter at the aperture (mm): ~2.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MPL-S-266-LP with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMPL-S-266-LP (current)MPL-Q-266MPL-Q1-266
Wavelength266 nm266 nm266 nm
Optical power / pulse energy1~15 mW1~30 mW10 mW
Operating mode / pulse width1 Hz-1 kHz3-12 kHz1 kHz
Beam qualityNear TEM00Near TEM00Near TEM00