Back to Home

Pulse energy, repetition rate, pulse width

LPS-532-S532 nm green Q-switched pulsed laser

532 nm

LPS-532-S is a 532 nm Pulsed laser. Used for ranging, medical treatment, scientific research, laser cosmetology. Key specifications: pulse energy 1-20 mJ, repetition rate ~10 Hz, operating mode Actively Q-switched. View specifications, datasheet and enquiry options from Precisometer.

Specifications

LPS-532-S

11 specification rows

Wavelength532 nm
Pulse energy1-20 mJ
Repetition rate~10 Hz
Operating modeActively Q-switched
Pulse duration (ms)0.9
energylamp / pumped / pulsed / laser / at
Beam diameter (mm)5
Warm-up time (minutes)<15
Cooled methodWater cooled
Operating temperature (℃)15-35
Power supply (110/220VAC)PSU-LPS-S
Expected lifetime (pulses)107

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Ranging

LPS-532-S: 532 nm emission determines compatible optics, coatings and detectors for Ranging. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Medical treatment

LPS-532-S: 532 nm emission determines compatible optics, coatings and detectors for Medical treatment. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Scientific research

LPS-532-S: 532 nm emission determines compatible optics, coatings and detectors for Scientific research. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Laser cosmetology

LPS-532-S: 532 nm emission determines compatible optics, coatings and detectors for Laser cosmetology. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

System integration

Integration and compatibility

Use these checks to connect LPS-532-S to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Water cooled · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam diameter (mm): 5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for LPS-532-S

What cooling does the LPS-532-S require?

Cooled method: Water cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the LPS-532-S deliver?

Beam diameter (mm): 5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare LPS-532-S with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterLPS-532-S (current)FS-H- 5 32AFS-H- 5 32B
Wavelength532 nm532 nm532 nm
Optical power / pulse energy1-20 mJ1-100 mW100-2000 mW
Operating mode / pulse width~10 HzPulsedPulsed
Beam qualityConfirm for this modelTEM00TEM00