ICP-MS
LPS-532-A: 532 nm emission determines compatible optics, coatings and detectors for ICP-MS. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
Pulse energy, repetition rate, pulse width
LPS-532-A is a 532 nm Pulsed laser. Used for icp-ms, raman, scientific research. Key specifications: pulse energy 1-10 mJ, repetition rate ~10 Hz, operating mode Actively Q-switched. View specifications, datasheet and enquiry options from Precisometer.
Specifications
19 specification rows
| Pulse energy | 1-10 mJ |
|---|---|
| Repetition rate | ~10 Hz |
| Operating mode | Actively Q-switched |
| Pulse duration (ns) | <12 / <10 |
| Jitter (ns, sdev) | <1ns (Int.) |
| energy | lamp / pumped / solid / state |
| of high single pulse energy ,short pulse | Beam divergence, full angle (mrad) / ~1.5 / ~1.0 |
| Beam diameter (mm) | <6 |
| Warm-up time (minutes) | <15 |
| Cooled method | Closed-loop liquid cooling |
| Operating temperature (℃) | 20-25 |
| Power supply (110/220VAC) | PSU-LPS-A(3U) |
| Expected lifetime of lamp (pulses) | 107-108 |
| Pulse width | Water to air cooled |
| Wavelength (nm) | 532±1 |
| Rep. rate | 1-10Hz (adjustable), single shot (optional) |
| Energy stability (std dev/mean) | <5%, <3%,(<2% optional) |
| Beam height from base plate (mm) | 123 |
| Available options | Accessories |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
LPS-532-A: 532 nm emission determines compatible optics, coatings and detectors for ICP-MS. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
LPS-532-A: 532 nm emission sets the excitation and detector-band choice for Raman; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line.
LPS-532-A: 532 nm emission determines compatible optics, coatings and detectors for Scientific research. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
System integration
Use these checks to connect LPS-532-A to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Closed-loop liquid cooling · Operating temperature (℃): 20-25. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam diameter (mm): <6. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare LPS-532-A with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | LPS-532-A (current) | FS-H- 5 32A | FS-H- 5 32B |
|---|---|---|---|
| Wavelength | 532 nm | 532 nm | 532 nm |
| Optical power / pulse energy | 1-10 mJ | 1-100 mW | 100-2000 mW |
| Operating mode / pulse width | ~10 Hz | Pulsed | Pulsed |
| Beam quality | Confirm for this model | TEM00 | TEM00 |
Compare the LPS-532-A with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide