CXPF100-80175 Motorized Linear Stage

Zolix · Motorized Stages

CXPF100-80175 Motorized Linear Stage

Motorized linear stage with 100 mm travel and an 80×175 mm table. Transmission: ball screw φ8×2; guide: crossed-roller bearing guides. Repositioning accuracy ≤±2 µm; max speed 20 mm/s. Horizontal load capacity 30 kg; weight 1.8 kg.

Travel range
100 mm
Repositioning accuracy
≤±2 µm
Horizontal load capacity
30 kg
Table size
80×175 mm
View quote list
CXPF Series High-Precise Motorized Linear Stages

Specifications

Mechanical

Travel range (mm)100
Table size (mm)80×175
Transmission mechanismBall screw φ8×2
Guide mechanismCrossed-roller bearing guides
Body material and finishBlack anodized aluminum-alloy
Weight (kg)1.8
Shaft coupling, OD-bore-bore (mm)16-5-5

Accuracy

Resolution, full/half step (µm)10/5
Resolution, 20× microstep (µm)0.5
Max speed (mm/s)20
Repositioning accuracy (µm)≤±2
Backlash (µm)≤3
Static parallelism (mm)≤0.1
Dynamic straightness (µm)≤10
Dynamic parallelism (µm)≤15
Minimum incremental motion (µm)≤2

Motor & electrical

Motor modelShinano, SST43D2126-10
Motor and step angle (°)Two-phase 42 stepping motor, 1.8
Insulation resistanceOver 100 MΩ/min
Insulation strength500 V AC for 1 minute, no abnormality
Insulation classClass B
Motor weight (kg)0.29
Motor voltage (V)2.8
Motor current (A/phase)1.7
Resistance (Ω/phase)1.65±10%
Inductance (mH/phase)3.6
Motor holding torque (N·m)0.456
Braking torque (N·m)0.005 (reference value)
Rotor inertia (g·cm²)56
Operating temperature (°C)0~+50
Max motor temperature (°C)80
Stepper driver (optional)Moons, SR2

Sensors & connection

ConnectorDB9 (pin)
Cable typeHigh flexibility cable (Helukabel, Germany)
Cable length (m)0.2
Limit sensors (built-in)2×GP1S09xHCP (SHARP, Japan)
Origin sensor (built-in)1×GP1S09xHCPI (SHARP, Japan)
Sensor supply voltageDC5-24V±10%
Sensor current consumption (mA)<60 (total)
Sensor outputNPN open-collector output DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA)
Sensor output logicOutput ON when sensor is blocked

Load capacity

Horizontal load capacity (kg)30
Vertical load capacity (kg)8
Inverted load capacity (kg)5

Compatible controllers

For the two-phase 42 stepping motor this stage uses.