Back to Home

Pulse energy, repetition rate, pulse width

MPL-U-1313-SU1313 nm infrared Q-switched pulsed laser

1313 nm

MPL-U-1313-SU is a 1313 nm Pulsed laser. Key specifications: output / average power 1~100 mW, pulse energy 1~20 uJ, wavelength (nm) 1313±1. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MPL-U-1313-SU

18 specification rows

Output / average power1~100 mW
Pulse energy1~20 uJ
Wavelength (nm)1313±1
Operating modePassively Q-switched
Single pulse energy (µJ)1-20
Pulse duration (ns)~15
Peak power (kW)0.1-1.3
Rep. rate1Hz-4kHz
Power stability (rms, 4 hours ±3°C)<5%, <3%, <2%
Transverse modeTEM00
<2.0
Beam diameter at the aperture (mm)~1.2
Beam divergence, full angle (mrad)<2.0
Warm-up time (minutes)<5
Beam height from base plate (mm)27.4
Operating temperature (℃)10-35
Power supply (100-240VAC)PSU-H-FDA/ PSU-SR
Expected lifetime (hours)>10000

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

MPL-U-1313-SU: 1313 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Laboratory measurement

MPL-U-1313-SU: Laboratory measurement benefits from a stable, focusable source. 1313 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect MPL-U-1313-SU to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M²: <2.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MPL-U-1313-SU

What cooling does the MPL-U-1313-SU require?

Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MPL-U-1313-SU deliver?

Transverse mode: TEM00 · M²: <2.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MPL-U-1313-SU with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMPL-U-1313-SU (current)MPL-H-1313MDL-NS-1310
Wavelength1313 nm1313 nm1310 nm
Optical power / pulse energy1~100 mW1~100 mW1~10 mW
Operating mode / pulse widthPassively Q-switchedPassively Q-switchedPulsed
Beam qualityTEM00TEM00Multimode