Back to Home

Pulse energy, repetition rate, pulse width

MPL-H-13131313 nm infrared Q-switched pulsed laser

1313 nm

MPL-H-1313 is a 1313 nm Pulsed laser. Fan cooling and heat sink. Key specifications: output / average power 1~100 mW, pulse energy 10~20 uJ, operating mode Passively Q-switched. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MPL-H-1313

21 specification rows

Output / average power1~100 mW
Pulse energy10~20 uJ
Beam / notesFan cooling and heat sink
Operating modePassively Q-switched
Transverse modeTEM00
Beam diameter at the aperture (mm)~1.5
Polarization ratio>100:1, Horizontal (Vertical optional)
Warm-up time (minutes)<5
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-H-FDA
Expected lifetime (hours)>10000
Wavelength (nm)1313±1
Max average power (mW)1-100
Single pulse energy (µJ)10-20
Pulse duration (ns)~18
Peak power (kW)0.55-1.1
Rep. rate (kHz)0.001-4
Ave power stability (over 4 hours)<3%, <2%, <1%
<1.5
Beam divergence, full angle (mrad)<2.0
Beam height from base plate (mm)29

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

MPL-H-1313: 1313 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Laboratory measurement

MPL-H-1313: Laboratory measurement benefits from a stable, focusable source. 1313 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect MPL-H-1313 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · Beam diameter at the aperture (mm): ~1.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MPL-H-1313

What cooling does the MPL-H-1313 require?

Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MPL-H-1313 deliver?

Transverse mode: TEM00 · Beam diameter at the aperture (mm): ~1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MPL-H-1313 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMPL-H-1313 (current)MPL-U-1313-SUMDL-NS-1310
Wavelength1313 nm1313 nm1310 nm
Optical power / pulse energy1~100 mW1~100 mW1~10 mW
Operating mode / pulse widthPassively Q-switchedPassively Q-switchedPulsed
Beam qualityTEM00TEM00Multimode