Back to Home

Pulse energy, repetition rate, pulse width

AO-Mini-E-13191319 nm infrared Q-switched pulsed laser

1319 nm

AO-Mini-E-1319 is a 1319 nm Pulsed laser. Q-switched Infrared Laser. Key specifications: operating mode Q-switched, output / average power 100~500 mW, pulse energy 10~100 uJ. View specifications, datasheet and enquiry options from Precisometer.

Specifications

AO-Mini-E-1319

15 specification rows

Operating modeQ-switched
Output / average power100~500 mW
Pulse energy10~100 uJ
Beam / notesQ-switched Infrared Laser
Power stability (rms, 4 hours ± 3°C)<3%, <2%,<1%
Warm-up time (minutes)<10
Cooled methodAir cooled
Operating temperature (℃)10-35
Operating voltage (VDC)24V/14.5A
Expected lifetime (hours)>10000
Wavelength (nm)1319±1
Rep. rate1-50kHz
Beam divergence, full angle (mrad)<2.0
Beam diameter at the aperture (1/e2, mm)~2.0
Beam height from base plate (mm)80.2

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

AO-Mini-E-1319: 1319 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (<2.0) helps predict how the source will focus and propagate through the instrument.

Laboratory measurement

AO-Mini-E-1319: Laboratory measurement benefits from a stable, focusable source. 1319 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<2.0) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect AO-Mini-E-1319 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <2.0 · Beam diameter at the aperture (1/e2, mm): ~2.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for AO-Mini-E-1319

What cooling does the AO-Mini-E-1319 require?

Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the AO-Mini-E-1319 deliver?

Beam divergence, full angle (mrad): <2.0 · Beam diameter at the aperture (1/e2, mm): ~2.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare AO-Mini-E-1319 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterAO-Mini-E-1319 (current)1319HPL-1319-Q
Wavelength1319 nm1319 nm1319 nm
Optical power / pulse energy100~500 mW20-50 W20-50 W
Operating mode / pulse widthQ-switchedQ-switchedQ-switched
Beam quality<2.0Confirm for this model<3.5