In PIV
LPS-1064-S: 1064 nm emission determines compatible optics, coatings and detectors for In PIV. The catalogued beam parameter (~1 / <3) helps predict how the source will focus and propagate through the instrument.
Pulse energy, repetition rate, pulse width
LPS-1064-S is a 1064 nm Pulsed laser. Used for in piv, icp-ms, raman, scientific research. Cooling: Water cooled. Key specifications: pulse energy 50-300 mJ, repetition rate 1-10 (<20 Hz optional), pulse width ~10 ns. View specifications, datasheet and enquiry options from Precisometer.
Specifications
20 specification rows
| Pulse energy | 50-300 mJ |
|---|---|
| Repetition rate | 1-10 (<20 Hz optional) |
| Pulse width | ~10 ns |
| Beam / notes | Cooling: Water cooled |
| Operating mode | Actively Q-switched |
| Jitter (ns, sdev) | <1ns (Int.) |
| energy | lamp / pumped / solid / state |
| pulse | energy, / short / pulse |
| Beam divergence, full angle (mrad) | ~1 / <3 |
| Beam diameter (mm) | <6 / ~7 |
| Warm-up time (minutes) | <15 |
| Cooled method | Water cooled |
| Operating temperature (℃) | 15-35 |
| Power supply (110/220VAC) | PSU-LPS-S (3U) |
| Expected lifetime (pulses) | 107-108 |
| Wavelength (nm) | 1064±1 |
| Rep. rate | 1-10Hz (adjustable), single shot (optional) |
| Energy stability (std dev/mean) | <3%, <2%, <1% |
| Beam height from base plate (mm) | 75 |
| Available options | Repetition rate≤20Hz;Accessories; |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
LPS-1064-S: 1064 nm emission determines compatible optics, coatings and detectors for In PIV. The catalogued beam parameter (~1 / <3) helps predict how the source will focus and propagate through the instrument.
LPS-1064-S: 1064 nm emission determines compatible optics, coatings and detectors for ICP-MS. The catalogued beam parameter (~1 / <3) helps predict how the source will focus and propagate through the instrument.
LPS-1064-S: 1064 nm emission sets the excitation and detector-band choice for Raman; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (~1 / <3) also controls focusing and collection geometry.
LPS-1064-S: 1064 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (~1 / <3) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect LPS-1064-S to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Water cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam divergence, full angle (mrad): ~1 / <3 · Beam diameter (mm): <6 / ~7. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare LPS-1064-S with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | LPS-1064-S (current) | FS-H- 10 64A | FS-H- 10 64B |
|---|---|---|---|
| Wavelength | 1064 nm | 1064 nm | 1064 nm |
| Optical power / pulse energy | 50-300 mJ | 1-500 mW | 500-5000 mW |
| Operating mode / pulse width | 1-10 (<20 Hz optional) | Pulsed | Pulsed |
| Beam quality | ~1 / <3 | TEM00 | TEM00 |
Compare the LPS-1064-S with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide