Back to Home

Pulse energy, repetition rate, pulse width

LPS-1064-A1064 nm near-infrared Q-switched pulsed laser

1064 nm

LPS-1064-A is a 1064 nm Pulsed laser. Used for icp-ms, raman, scientific research. Key specifications: pulse energy 1-10 mJ, repetition rate ~10 Hz, operating mode Actively Q-switched. View specifications, datasheet and enquiry options from Precisometer.

Specifications

LPS-1064-A

19 specification rows

Pulse energy1-10 mJ
Repetition rate~10 Hz
Operating modeActively Q-switched
Pulse duration (ns)<10
Jitter (ns, sdev)<1ns (Int.)
energylamp / pumped / solid / state
Beam divergence, full angle (mrad)~2 / ~1
Beam diameter (mm)<6
Warm-up time (minutes)<15
Cooled methodClosed-loop liquid cooling
Operating temperature (℃)20-25
Power supply (110/220VAC)PSU-LPS-A(3U)
Expected lifetime of lamp (pulses)107-108
Pulse widthWater to air cooled
Wavelength (nm)1064±1
Rep. rate1-10Hz (adjustable), single shot (optional)
Energy stability (std dev/mean)<5%, <3%, <2%
Beam height from base plate (mm)123
Available optionsAccessories

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

ICP-MS

LPS-1064-A: 1064 nm emission determines compatible optics, coatings and detectors for ICP-MS. The catalogued beam parameter (~2 / ~1) helps predict how the source will focus and propagate through the instrument.

Raman

LPS-1064-A: 1064 nm emission sets the excitation and detector-band choice for Raman; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (~2 / ~1) also controls focusing and collection geometry.

Scientific research

LPS-1064-A: 1064 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (~2 / ~1) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect LPS-1064-A to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Closed-loop liquid cooling · Operating temperature (℃): 20-25
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): ~2 / ~1 · Beam diameter (mm): <6
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for LPS-1064-A

What cooling does the LPS-1064-A require?

Cooled method: Closed-loop liquid cooling · Operating temperature (℃): 20-25. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the LPS-1064-A deliver?

Beam divergence, full angle (mrad): ~2 / ~1 · Beam diameter (mm): <6. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare LPS-1064-A with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterLPS-1064-A (current)FS-H- 10 64AFS-H- 10 64B
Wavelength1064 nm1064 nm1064 nm
Optical power / pulse energy1-10 mJ1-500 mW500-5000 mW
Operating mode / pulse width~10 HzPulsedPulsed
Beam quality~2 / ~1TEM00TEM00