Sapphire marking
FS-G-1030B: Sapphire marking depends on how optical energy is delivered to the target; 1030 nm emission governs absorption, while the listed temporal parameter (<800) governs peak intensity and heat deposition.
Pulse energy, repetition rate, pulse width
FS-G-1030B is a 1030 nm Pulsed laser. Used for sapphire marking, ceramic cutting, semiconductor cutting, film scribing. <800fs @200KHz. Key specifications: operating mode Pulsed, output / average power 10~40 W, rep. rate (khz) 50-1000. View specifications, datasheet and enquiry options from Precisometer.
Specifications
22 specification rows
| Operating mode | Pulsed |
|---|---|
| Output / average power | 10~40 W |
| Beam / notes | <800 fs @200 kHz |
| Rep. rate (kHz) | 50-1000 |
| Pulse duration | <800 |
| Warm-up time (minutes) | <10 |
| Transverse mode | TEM00 |
| M2 factor | <1.3 |
| Polarization ratio | >100:1 Vertical |
| Cooled method | Water cooled |
| Operating temperature (℃) | 15-35 |
| Power supply (100-240VAC) | RAD1PS |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 1030±5 |
| Average power (W) | 10-40 (40W@200kHz) |
| Single pulse energy ( μJ) | 100-600 (600μJ@50kHz) |
| Peak power (MW) | 125-750 |
| Ave power stability (rms, 4 hours±3℃) | <2%, <1% |
| M² | <1.3 |
| Beam divergence, full angle (mrad) | <1.0 |
| Beam diameter at the aperture (1/e2,mm) | <3 |
| Beam height from base plate (mm) | 110 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
FS-G-1030B: Sapphire marking depends on how optical energy is delivered to the target; 1030 nm emission governs absorption, while the listed temporal parameter (<800) governs peak intensity and heat deposition.
FS-G-1030B: 1030 nm emission determines compatible optics, coatings and detectors for Ceramic cutting. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
FS-G-1030B: 1030 nm emission determines compatible optics, coatings and detectors for Semiconductor cutting. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
FS-G-1030B: 1030 nm emission determines compatible optics, coatings and detectors for Film scribing. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect FS-G-1030B to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Water cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Transverse mode: TEM00 · M2 factor: <1.3. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare FS-G-1030B with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | FS-G-1030B (current) | FS-H- 1030A | FS-H- 1030B |
|---|---|---|---|
| Wavelength | 1030 nm | 1030 nm | 1030 nm |
| Optical power / pulse energy | 10~40 W | 1-500 mW | 500-3000 mW |
| Operating mode / pulse width | Pulsed | Pulsed | Pulsed |
| Beam quality | TEM00 | TEM00 | TEM00 |
Compare the FS-G-1030B with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide