FL-1940-CW is a 1940 nm Fiber laser. Used for pump for medical surgery, plastic welding, cutting, non-metal materials processing. Infrared Fiber Laser. Key specifications: output / average power 1~100 W, operating mode CW, power stability (rms, 4 hours, ±3℃) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
Pump for medical surgery
FL-1940-CW: 1940 nm emission determines compatible optics, coatings and detectors for Pump for medical surgery. The catalogued beam parameter (<1.5) helps predict how the source will focus and propagate through the instrument.
Plastic welding
FL-1940-CW: 1940 nm emission determines compatible optics, coatings and detectors for Plastic welding. The catalogued beam parameter (<1.5) helps predict how the source will focus and propagate through the instrument.
Cutting
FL-1940-CW: 1940 nm emission determines compatible optics, coatings and detectors for Cutting. The catalogued beam parameter (<1.5) helps predict how the source will focus and propagate through the instrument.
Non-metal materials processing
FL-1940-CW: Non-metal materials processing depends on how optical energy is delivered to the target; 1940 nm emission governs absorption, while pulse energy, duration and repetition rate governs peak intensity and heat deposition.
System integration
Integration and compatibility
Use these checks to connect FL-1940-CW to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Fiber delivery interface
Fiber connector: Collimator
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Air cooled (≤30W) / Water cooled (>30W) · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for FL-1940-CW
How is the FL-1940-CW output delivered?+
Fiber connector: Collimator. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
What cooling does the FL-1940-CW require?+
Cooled method: Air cooled (≤30W) / Water cooled (>30W) · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the FL-1940-CW deliver?+
M2: <1.5 · Beam diameter (mm): ~7mm (Collimator outptut). Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.