FL-1908-LN-L is a 1908 nm Fiber laser. Used for optical communication, light detection, ranging, scientific research. Fiber laser Low Noise Infrared Laser. Key specifications: output / average power 1~5 W, operating mode CW, power stability (rms, 4 hours, ±3℃) <2%, <1%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

FL-1908-LN-L

27 specification rows

Output / average power1~5 W
Beam / notesFiber laser Low Noise Infrared Laser
Operating modeCW
Power stability (rms, 4 hours, ±3℃)<2%, <1%
Transverse modeTEM00
Longitudinal modeSLM
Current adjustment range1-100%
Spectral linewidth (nm)<0.006
Relative intensity noise (rms,10Hz-3MHz)<0.1%, <0.05%
M2<1.1
Fiber connectorFC/APC, Collimator optional
Fiber length(m)1
Fiber jacketPVC, Metal optional
Pointing stability (urad)<5 / <10
Polarization ratio (dB)>15, after PM fiber
Warm-up time (minutes)<30
Cooled methodAir cooled or Water cooled
Operating temperature (℃)15-30
Power supply (VAC)110/220VAC
Expected lifetime (hours)>10000
Wavelength (nm)1908±1
Output power (W)1-5
Frequency shift (MHz)(over ±2℃and 8hours )<±200
<1.1
Beam diameter (mm)4±1@Collimator output
Dimensions of Laser483×452 ×133mm3@Air cooled 483×461 ×120 mm3@Water cooled
Weight of Laser10kg@Air cooled, 11kg@Water cooled

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Optical communication

FL-1908-LN-L: 1908 nm emission must sit inside the fiber-component passband used for Optical communication; connector polish, fiber mode, linewidth and back-reflection tolerance should be specified as one optical interface.

Light detection

FL-1908-LN-L: 1908 nm emission determines compatible optics, coatings and detectors for Light detection. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Ranging

FL-1908-LN-L: 1908 nm emission determines compatible optics, coatings and detectors for Ranging. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Scientific research

FL-1908-LN-L: 1908 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect FL-1908-LN-L to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber connector: FC/APC, Collimator optional
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Air cooled or Water cooled · Operating temperature (℃): 15-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <1.1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Mechanical envelope
Dimensions of Laser: 483×452 ×133mm3@Air cooled 483×461 ×120 mm3@Water cooled · Weight of Laser: 10kg@Air cooled, 11kg@Water cooled
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Technical FAQ

Integration questions for FL-1908-LN-L

How is the FL-1908-LN-L output delivered?

Fiber connector: FC/APC, Collimator optional. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the FL-1908-LN-L require?

Cooled method: Air cooled or Water cooled · Operating temperature (℃): 15-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the FL-1908-LN-L deliver?

Transverse mode: TEM00 · M2: <1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

How is the FL-1908-LN-L mounted?

Dimensions of Laser: 483×452 ×133mm3@Air cooled 483×461 ×120 mm3@Water cooled · Weight of Laser: 10kg@Air cooled, 11kg@Water cooled. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare FL-1908-LN-L with the closest available models in the Fiber Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterFL-1908-LN-L (current)FL-1908-SLM1908
Wavelength1908 nm1908 nm1908 nm
Optical power / pulse energy1~5 W1~5 W1~5000 mW
Operating mode / pulse widthCWCWPulsed
Beam qualityTEM00TEM00<1.1