Back to Home

Fiber output, PM options, seed formats

19081908 nm infrared narrow-linewidth low-noise fiber laser

1908 nm

1908 is a 1908 nm Fiber laser. Used for optical microscope, photon imaging, physics experiment. M²: <1.1. Key specifications: output / average power 1~5000 mW, spectral linewidth <50 kHz, optical noise <0.05% RIN(DC-3 MHz). View specifications, datasheet and enquiry options from Precisometer.

Specifications

1908

18 specification rows

Wavelength1908 nm
Output / average power1~5000 mW
Spectral linewidth<50 kHz
Optical noise<0.05% RIN(DC-3 MHz)
<1.1
Operating modePulsed
Single pulse energy (nJ)0.1-0.6
Rep. rate (MHz)80±2
Ave power stability (rms, 4 hours±3℃)<2%, <1%
pulseduration, / high
Warm-up time (minutes)<10
Transverse modeTEM00
M2 factor<1.2
Polarization ratio>100:1 Vertical
Cooled methodAir cooled
Operating temperature (℃)10-35
Power supply (100-240VAC)12V/6.67A
Expected lifetime (hours)>10000
Frequency doublerLASER HEAD (780) / POWER SUPPLY

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Optical microscope

1908: 1908 nm emission can be matched to the absorption or excitation band used in Optical microscope. The stated stability or noise figure (<0.05% RIN(DC-3 MHz)) helps keep measured intensity changes attributable to the sample rather than source drift.

Photon imaging

1908: 1908 nm emission can be matched to the absorption or excitation band used in Photon imaging. The stated stability or noise figure (<0.05% RIN(DC-3 MHz)) helps keep measured intensity changes attributable to the sample rather than source drift.

Physics experiment

1908: Physics experiment benefits from a stable, focusable source. 1908 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<1.1) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect 1908 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
M²: <1.1 · Transverse mode: TEM00
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for 1908

What cooling does the 1908 require?

Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the 1908 deliver?

M²: <1.1 · Transverse mode: TEM00. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare 1908 with the closest available models in the Fiber Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameter1908 (current)FL-1908-SLMFL-1908-LN-L
Wavelength1908 nm1908 nm1908 nm
Optical power / pulse energy1~5000 mW1~5 W1~5 W
Operating mode / pulse widthPulsedCWCW
Beam quality<1.1TEM00TEM00