Back to Home

Fiber output, PM options, seed formats

FC-W-1908B1908 nm infrared high-power fiber laser

1908 nm

FC-W-1908B is a 1908 nm Fiber laser. Used for pumping, scientific research, industrial, medical applications. 1900 nm Infrared Diode Laser. Key specifications: output / average power 10~60 W, operating mode CW, after fiber output power (w) >10, 11, …, 20 / 20~60(On request). View specifications, datasheet and enquiry options from Precisometer.

Specifications

FC-W-1908B

19 specification rows

Output / average power10~60 W
Beam / notes1900 nm Infrared Diode Laser
Operating modeCW
After fiber output power (W)>10, 11, …, 20 / 20~60(On request)
Power stability (rms, over 4 hours)<2%, <1%, <0.5%
Fiber core diameter (μm)400/600
Fiber NA0.22
Fiber connectorSMA905
Fiber length (m)2
Operating temperature (℃)10~40
TTL / Analog modulationTTL or Analog with 1Hz-1kHz 1kHz-10kHz, 10kHz-30kHz optional
Cooling WayAir Cooled / Water Cooled
Dimensions(mm3)370 (L) ×406 (W) ×188 (H) / On request
Expected lifetime (hours)10000
Warranty1 year
Wavelength (nm)1908±10
Red pilot lightAvailable on request
LED displayDiode current
Input power100-240VAC, 50 to 60 Hz

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Pumping

FC-W-1908B: 1908 nm emission determines compatible optics, coatings and detectors for Pumping. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Scientific research

FC-W-1908B: 1908 nm emission determines compatible optics, coatings and detectors for Scientific research. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Industrial

FC-W-1908B: 1908 nm emission determines compatible optics, coatings and detectors for Industrial. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Medical applications

FC-W-1908B: 1908 nm emission determines compatible optics, coatings and detectors for Medical applications. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

System integration

Integration and compatibility

Use these checks to connect FC-W-1908B to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber core diameter (μm): 400/600 · Fiber NA: 0.22
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Operating temperature (℃): 10~40 · Cooling Way: Air Cooled / Water Cooled
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Mechanical envelope
Dimensions(mm3): 370 (L) ×406 (W) ×188 (H) / On request
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Technical FAQ

Integration questions for FC-W-1908B

How is the FC-W-1908B output delivered?

Fiber core diameter (μm): 400/600 · Fiber NA: 0.22. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the FC-W-1908B require?

Operating temperature (℃): 10~40 · Cooling Way: Air Cooled / Water Cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

How is the FC-W-1908B mounted?

Dimensions(mm3): 370 (L) ×406 (W) ×188 (H) / On request. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare FC-W-1908B with the closest available models in the Fiber Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterFC-W-1908B (current)FL-1908-SLMFL-1908-LN-L
Wavelength1908 nm1908 nm1908 nm
Optical power / pulse energy10~60 W1~5 W1~5 W
Operating mode / pulse widthCWCWCW
Beam qualityConfirm for this modelTEM00TEM00