EO-1064-Subnano-Hi is a 1064 nm Pulsed laser. Used for scanning imaging radar, laser ranging. Cooling: Air or Water Cooled. Key specifications: pulse energy 1-4000 uJ, repetition rate 10 Hz-10 kHz, pulse width <1.5 ns @<5 kHz. View specifications, datasheet and enquiry options from Precisometer.
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
Scanning imaging radar
EO-1064-Subnano-Hi: 1064 nm emission determines compatible optics, coatings and detectors for Scanning imaging radar. The catalogued beam parameter (<3mrad) helps predict how the source will focus and propagate through the instrument.
Laser ranging
EO-1064-Subnano-Hi: 1064 nm emission determines compatible optics, coatings and detectors for Laser ranging. The catalogued beam parameter (<3mrad) helps predict how the source will focus and propagate through the instrument.
System integration
Integration and compatibility
Use these checks to connect EO-1064-Subnano-Hi to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Air cooled or water cooled · Operating temperature (℃): 15-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for EO-1064-Subnano-Hi
How is the EO-1064-Subnano-Hi output delivered?+
Fiber core diameter: 1mm, 0.22NA · Fiber connector: SMA905. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
What cooling does the EO-1064-Subnano-Hi require?+
Cooled method: Air cooled or water cooled · Operating temperature (℃): 15-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the EO-1064-Subnano-Hi deliver?+
Beam diameter (mm): ~2mm / ~2.5mm · Beam divergence, full angle (mrad): <3mrad. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare EO-1064-Subnano-Hi with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.