Back to Home

Pulse energy, repetition rate, pulse width

DPS-1064-PIV1064 nm near-infrared Q-switched pulsed laser

1064 nm

DPS-1064-PIV is a 1064 nm Pulsed laser. Used for icp-ms, lcd repair, scientific research. Key specifications: pulse energy 1-20 mJ, repetition rate <10 Hz, beam divergence, full angle (mrad) ≤3. View specifications, datasheet and enquiry options from Precisometer.

Specifications

DPS-1064-PIV

17 specification rows

Pulse energy1-20 mJ
Repetition rate<10 Hz
Beam divergence, full angle (mrad)≤3
Warm-up time (minutes)<15
Cooled methodAir cooled
Operating temperature (℃)-20-55
Operating voltage (VDC)24V/25A
Expected lifetime (pulses)10 9
Delay between two pulses (ns)0-50000
Wavelength (nm)1064±1
Operating modeActively Q-switched
Single pulse energy (mJ)100@Single pulse
Pulse duration (ns)<10
Rep. rate10-20Hz (adjustable)
Energy stability (std dev/mean)<2%, <1%, <0.5%
Beam diameter (mm)~5
Beam height from base plate (mm)30.5

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

ICP-MS

DPS-1064-PIV: 1064 nm emission determines compatible optics, coatings and detectors for ICP-MS. The catalogued beam parameter (≤3) helps predict how the source will focus and propagate through the instrument.

LCD repair

DPS-1064-PIV: 1064 nm emission determines compatible optics, coatings and detectors for LCD repair. The catalogued beam parameter (≤3) helps predict how the source will focus and propagate through the instrument.

Scientific research

DPS-1064-PIV: 1064 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (≤3) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect DPS-1064-PIV to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (℃): -20-55
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): ≤3 · Beam diameter (mm): ~5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for DPS-1064-PIV

What cooling does the DPS-1064-PIV require?

Cooled method: Air cooled · Operating temperature (℃): -20-55. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the DPS-1064-PIV deliver?

Beam divergence, full angle (mrad): ≤3 · Beam diameter (mm): ~5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare DPS-1064-PIV with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterDPS-1064-PIV (current)FS-H- 10 64AFS-H- 10 64B
Wavelength1064 nm1064 nm1064 nm
Optical power / pulse energy1-20 mJ1-500 mW500-5000 mW
Operating mode / pulse width<10 HzPulsedPulsed
Beam quality≤3TEM00TEM00