Back to Home

Pulse energy, repetition rate, pulse width

AO-266A266 nm deep-UV Q-switched pulsed laser

266 nm

AO-266A is a 266 nm Pulsed laser. Used for laser radar, scientific research,precision research. Key specifications: output / average power 100~200 mW, pulse energy 4~7 uJ, repetition rate 20-200 kHz. View specifications, datasheet and enquiry options from Precisometer.

Specifications

AO-266A

20 specification rows

Output / average power100~200 mW
Pulse energy4~7 uJ
Repetition rate20-200 kHz
Pulse width~10 ns @30 kHz
Operating modeActively Q-switched
Power stability (rms, 4 hours ± 3°C)<2%,<1%
Transverse modeTEM00
Beam divergence, full angle (mrad)<3.5
M2<1.2
Polarization ratio>100:1 Horizontal
Warm-up time (minutes)<10
Cooled methodAir cooled
Operating temperature (℃)10-35
Operating voltage (VDC)12V/25A
Expected lifetime (hours)>10000
Wavelength (nm)266±1
Pulse duration (ns)~10@30kHz
Beam diameter at the aperture (1/e2, mm)~1
<1.2
Beam height from base plate (mm)80.5

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Laser radar

AO-266A: 266 nm emission determines compatible optics, coatings and detectors for Laser radar. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Scientific research,precision research

AO-266A: 266 nm emission determines compatible optics, coatings and detectors for Scientific research,precision research. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect AO-266A to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · Beam divergence, full angle (mrad): <3.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for AO-266A

What cooling does the AO-266A require?

Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the AO-266A deliver?

Transverse mode: TEM00 · Beam divergence, full angle (mrad): <3.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare AO-266A with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterAO-266A (current)MPL-Q-266MPL-Q1-266
Wavelength266 nm266 nm266 nm
Optical power / pulse energy100~200 mW1~30 mW10 mW
Operating mode / pulse width20-200 kHz3-12 kHz1 kHz
Beam qualityTEM00Near TEM00Near TEM00