Optical microscope
266: 266 nm emission can be matched to the absorption or excitation band used in Optical microscope. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
Pulse energy, repetition rate, pulse width
266 is a 266 nm Pulsed laser. Used for optical microscope, photon imaging, physics experiment. Rep. rate (Hz): 1kHz-5kHz; Cooled method: Air cooled. Key specifications: pulse energy 1-100 uJ, repetition rate 1 kHz-5 kHz, pulse width <2@<1 kHz. View specifications, datasheet and enquiry options from Precisometer.
Specifications
5 specification rows
| Wavelength | 266 nm |
|---|---|
| Pulse energy | 1-100 uJ |
| Repetition rate | 1 kHz-5 kHz |
| Beam / notes | Rep. rate (Hz): 1 kHz-5 kHz; Cooled method: Air cooled |
| Pulse width | <2@<1 kHz |
| Cooling | Air cooled |
Application context
Applications named on a datasheet for this product line, interpreted against this model’s listed wavelength and beam data.
266: 266 nm emission can be matched to the absorption or excitation band used in Optical microscope. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
266: 266 nm emission can be matched to the absorption or excitation band used in Photon imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
266: Physics experiment benefits from a stable, focusable source. 266 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.
System integration
Use these checks to connect 266 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooling: Air cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare 266 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | 266 (current) | MPL-Q-266 | MPL-Q1-266 |
|---|---|---|---|
| Wavelength | 266 nm | 266 nm | 266 nm |
| Optical power / pulse energy | 1-100 uJ | 1~30 mW | 10 mW |
| Operating mode / pulse width | 1 kHz-5 kHz | 3-12 kHz | 1 kHz |
| Beam quality | Confirm for this model | Near TEM00 | Near TEM00 |
Compare the 266 with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide