Compare the details
Technical specifications
Compare the listed configurations and match the specifications to your setup.
4 specification rows.
Light-sheet optics
4 entries| Parameter | Listed capability |
|---|---|
| Operating distance | 100–30000 mm; continuously adjustable |
| Minimum sheet thickness | 0.5 mm; confirm at the selected working distance and input beam |
| Fan / divergence angle | 20°, 30°, 60° or custom |
| Construction | Compact optical assembly |
Build around your experiment
What to specify
Share these details with your enquiry so we can match the component to your optical setup.
- 01Working distance, illuminated field height and desired sheet thickness at the test section.
- 02Laser wavelength, input beam diameter, divergence and CW power or pulse energy.
- 03Optical access, mounting, coating and damage-threshold requirements.
Application context
Applications
- Planar PIV and flow visualization
Technical FAQ
Configuration questions for PIV Laser Light Sheet
Is 0.5 mm sheet thickness available at every distance?
- The listed minimum is 0.5 mm, with an adjustable operating-distance range of 100–30000 mm. These figures do not guarantee that thickness across the entire range. Confirm the thickness and uniformity at the selected distance with the actual input beam.
Technical documents
Keep the specifications at hand when planning your setup.
Download datasheet (PDF)Talk through your setup
Find the right configuration
Add this component to your enquiry and include your requirements. We will help specify the variant, interfaces and mounting.