Back to Home

Microscopy Camera/Microscope Camera

UHCCD01400KPA

UHCCD01400KPA Microscopy Camera/Microscope Camera with ICX205AK CCD (C) sensor, 1.4MP (1360×1024) for professional imaging.

Sensor
ICX205AK CCD (C)
Resolution
1.4MP (1360×1024)
Pixel Size
4.65 µm × 4.65 µm
Frame Rate
8 fps @ 1360×1024
Interface
USB2.0
UHCCD01400KPA

Application context

Why this design is used

Scientific imaging

UHCCD01400KPA: The ICX205AK CCD (C) sensor, 1.4MP (1360×1024) resolution, and 4.65 µm × 4.65 µm pixels defines the sensitivity, sampling and field coverage available for Scientific imaging. The 8 fps @ 1360×1024 frame-rate listing also sets the fastest full-frame acquisition regime.

Instrument integration

UHCCD01400KPA: The ICX205AK CCD (C) sensor, 1.4MP (1360×1024) resolution, and 4.65 µm × 4.65 µm pixels defines the sensitivity, sampling and field coverage available for Instrument integration. The 8 fps @ 1360×1024 frame-rate listing also sets the fastest full-frame acquisition regime.

Specifications

UHCCD01400KPA

23 specification rows

The UHCCD01400KPA is a microscopy camera in the UHCCD series, built around a ICX205AK CCD (C) sensor, 1.4MP (1360×1024) resolution, 4.65 µm × 4.65 µm pixels, frame rates up to 8 fps @ 1360×1024, a USB2.0 interface. It suits microscopy camera/microscope camera where reliable imaging performance and interface compatibility matter.

Key Parameters

ModelUHCCD01400KPA
SensorICX205AK CCD (C)
Effective Pixels / Resolution1.4MP (1360×1024)
Frame Rate (Full Resolution)8 fps @ 1360×1024
Exposure Time0.227 ms ~ 60 s
Shutter TypeRolling Shutter
Color TypeColor

Imaging Performance

Pixel Size4.65 µm × 4.65 µm
Sensor Size6.32 mm × 4.76 mm
Diagonal1/2" (7.91 mm)
Dynamic RangeAvailable on request
Bit Depth8-bit/12-bit
Sensitivity400 mv with 1/30s

Interface & Mechanical

Data InterfaceUSB2.0
GPIOAvailable on request
Lens MountC-mount
DimensionsAvailable on request
Weight0.67~0.8 Kg
Power SupplyUSB2.0 Power Supply

Environment & Certification

Operating Temperature / Humidity10 °C ~ +50 °C / 30%~80%RH
Storage Temperature / Humidity20 °C ~ +60 °C / 10%~60%RH
Operating SystemWindows XP/Vista/7/8/10/11(32&64-bit)/OS X/Linux
CertificationCE, FCC

System integration

Integration and compatibility

Use these checks to connect UHCCD01400KPA to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Lens and microscope interface
Lens Mount: C-mount
Use a lens image circle that covers the sensor and check flange distance before adding C/CS, F-mount or M42 adapters.
Sensor and sampling
Sensor: ICX205AK CCD (C) · Resolution: 1.4MP (1360×1024)
Match pixel pitch to the diffraction-limited spot the optics deliver. Sampling finer than the optics resolve multiplies data volume without adding information; sampling coarser discards resolution you have paid for.
Interface and data rate
Frame Rate: 8 fps @ 1360×1024 · Interface: USB2.0
Confirm the host can sustain the interface bandwidth continuously, not in burst. A camera that outruns the write path stalls acquisition rather than dropping quietly to a lower rate.
Hardware synchronization
GPIO: Available on request
Confirm edge polarity, pulse-width limits and whether each line is opto-isolated before connecting TTL or GPIO signals. A software exposure command is not equivalent to a hardware trigger.
Cooling and noise floor
Dynamic Range: Available on request
Judge these figures at the exposure time you will actually use. Cooling matters where dark current accumulates over seconds; read noise dominates short exposures where it never does.

Technical FAQ

Integration questions for UHCCD01400KPA

What lens mount is required for the UHCCD01400KPA?

Lens Mount: C-mount. Use a lens image circle that covers the sensor and check flange distance before adding C/CS, F-mount or M42 adapters.

What sensor and pixel pitch does the UHCCD01400KPA use?

Sensor: ICX205AK CCD (C) · Resolution: 1.4MP (1360×1024). Match pixel pitch to the diffraction-limited spot the optics deliver. Sampling finer than the optics resolve multiplies data volume without adding information; sampling coarser discards resolution you have paid for.

How does the UHCCD01400KPA connect to the acquisition computer?

Frame Rate: 8 fps @ 1360×1024 · Interface: USB2.0. Confirm the host can sustain the interface bandwidth continuously, not in burst. A camera that outruns the write path stalls acquisition rather than dropping quietly to a lower rate.

Does the UHCCD01400KPA support hardware triggering?

GPIO: Available on request. Confirm edge polarity, pulse-width limits and whether each line is opto-isolated before connecting TTL or GPIO signals. A software exposure command is not equivalent to a hardware trigger.

What is the noise performance of the UHCCD01400KPA?

Dynamic Range: Available on request. Judge these figures at the exposure time you will actually use. Cooling matters where dark current accumulates over seconds; read noise dominates short exposures where it never does.

Need help choosing?

Tell us your sensor, resolution, spectral range, frame-rate, interface, and software requirements and we will confirm the matching configuration and lead time.

Open camera finder

Model selection

Nearby series comparison

Compare UHCCD01400KPA with the closest available models in the UHCCD family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterUHCCD01400KPA (current)UHCCD01400KMBUHCCD01400KPB
SensorICX205AK CCD (C)ICX205AL CCD (M)ICX205AK CCD (C)
Resolution1.4MP (1360×1024)1.4MP (1360×1024)1.4MP (1360×1024)
Sensor size6.32 mm × 4.76 mm6.32 mm × 4.76 mm6.32 mm × 4.76 mm
Pixel size / frame rate4.65 µm × 4.65 µm4.65 µm × 4.65 µm4.65 µm × 4.65 µm

Other cameras on the ICX205 sensor

The ICX205 appears in 3 models across the catalogue, differing in cooling, shutter, interface and colour filter. Compare them side by side before settling on a variant.