Automated scanning and mapping
Step-and-acquire across areas far wider than a single field of view.

Opto-Mechanics · Motorized XY Series All-In-One Two-Axis Stages
XY motorized automatic alignment stage; 120 mm x 120 mm XY travel/platform class; integrated two-axis assembly; translation repeatability around +/-1 um.
Datasheet (PDF) ↗CAD Model (RAR) ↗Catalog context
XY120120 is listed in the Motorized XY Series All-In-One Two-Axis Stages family. The local catalog record provides these first selection fields: Travel range ( mm ): X axis:120 Y axis:120; Stage surface size(mm): 280×280; Central light-through hole dimension (mm): 188×188.
| Travel range ( mm ) | X axis:120 Y axis:120 |
|---|---|
| Stage surface size(mm) | 280×280 |
| Central light-through hole dimension (mm) | 188×188 |
| Light-through dimension at extreme position (mm) | 128×128 |
| Transmission mechanism | precision ball screw,φ16×4 |
| Guides(guiding mechanism) | crossed-roller bearing guides |
| Main body material and surface treatment | Black anodized aluminum alloy |
| Shaft coupling (external diameter- diameter of aperture 1-diameter of aperture 2) (mm) | 20/5/10 |
| Weight(Kg) | 7 |
| Resolution (step/half-step) (µm) | 20/10 |
| 20-fine-subdivision resolution (µm) | 1 |
| Max speed(mm/s)* | 40 |
| Repositioning accuracy (um) | ≤±3 |
| Backlash(um) | ≤5 |
| Static parallelism (mm) | ≤0.1 |
| Motion straightness(um/100mm) | ≤10 |
| Motional parallelism (um) | ≤25 |
| Error on orthogonality (um) | ≤60 |
| Brand and model number of motor | Shinano,SST43D2126 |
| Working current(A) | 1.7 |
| Holding torque of motor (N·m) | 0.456 |
| Brand and model number of stepping driver (optional) | Moons, SR2 |
| Type of plug for stage | DB9(pin) |
| Type of cable for stage | High flexibility cable (Helukabel, Germany) |
| Length of connection cable(m) | 0.2 |
| Position-limit sensors (built-in), for each axis | 2*PM-L25 (SUNX, Japan) |
| Voltage of power supply for sensors (V) | DC5~24V±10% |
| Control output | NPN open collector output; DC5~24v 50mA or less |
| Status of output ports | Output ON when sensor is blocked |
| Vertical direction(Kg) | 20 |
Application context
Application guidance is derived from the product family and tied to the model-specific selection fields above.
Step-and-acquire across areas far wider than a single field of view.
Move parts between fixed stations with closed-loop encoders holding position over long shifts.
Coordinate several axes from software for processing, inspection and test sequences.
System integration
Use these checks to connect XY120120 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Travel range ( mm ): X axis:120 Y axis:120 · Resolution (step/half-step) (µm): 20/10. Separate travel from resolution and both from repeatability. Repeatability is what an automated sequence actually depends on, and it is the figure most often absent from a headline specification.
Brand and model number of motor: Shinano,SST43D2126 · Holding torque of motor (N·m): 0.456. Pair open-loop mechanics with the specified high-voltage or inertial driver, and closed-loop variants with the controller their capacitive, strain-gauge or encoder feedback requires. Matching connectors do not guarantee electrical compatibility.
Central light-through hole dimension (mm): 188×188. Check the load rating in the orientation you will use it — a vertical or cantilevered load is a moment, not a mass — and match the base to an M6 pattern on a 25 mm grid or a 1/4"-20 pattern on a 1 inch grid.
Model selection
Compare XY120120 with the closest available models in the Motorized XY Series All-In-One Two-Axis Stages family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | XY120120 (current) | XY5050 |
|---|---|---|
| Travel / adjustment | X axis:120 Y axis:120 | X axis:50 Y axis:50 |
| Resolution / sensitivity | 20/10 | 5/2.5 |
| Load / optic size | 20/5/10 | 13/3/5 |
| Mounting interface | 188×188 | 60×64 |
Before you specify
Engineering context for choosing this class of component, with the tradeoffs worked through on real specifications.
Precision motionTranslate temperature, pressure, travel, payload, feedback, and motion requirements into a defensible cryogenic-stage shortlist.
Open guide
Opto-mechanicsVibration, thermal drift and mechanical integration are one problem. Budget the motion at the sample, then specify the table, the isolation, the mounts and the beam height that budget asks for.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide