Back to Home
XY5050

Opto-Mechanics · Motorized XY Series All-In-One Two-Axis Stages

XY5050

XY motorized automatic alignment stage; 50 mm x 50 mm XY travel/platform class; integrated two-axis assembly; translation repeatability around +/-1 um.

View quote list
Datasheet (PDF) ↗CAD Model (RAR) ↗

Catalog context

Where XY5050 fits

XY5050 is listed in the Motorized XY Series All-In-One Two-Axis Stages family. The local catalog record provides these first selection fields: Travel range ( mm ): X axis:50 Y axis:50; Stage surface size(mm): 125×125; Central light-through hole dimension (mm): 60×64.

Specifications

Travel range ( mm )X axis:50 Y axis:50
Stage surface size(mm)125×125
Central light-through hole dimension (mm)60×64
Light-through dimension at extreme position (mm)35×47
Transmission mechanismprecision ball screw,φ6×1
Guides(guiding mechanism)crossed-roller bearing guides
Main body material and surface treatmentBlack anodized aluminum alloy
Shaft coupling (external diameter- diameter of aperture 1-diameter of aperture 2) (mm)13/3/5
Weight(Kg)2.2
Resolution (step/half-step) (µm)5/2.5
20-fine-subdivision resolution (µm)0.25
Max speed(mm/s)*10
Repositioning accuracy (um)≤±1.5
Backlash(um)≤3
Static parallelism (mm)≤0.1
Motion straightness(um/100mm)≤10
Motional parallelism (um)≤25
Error on orthogonality (um)≤15
Brand and model number of motorShinano,STP-28D1003-08
Working current(A)1.3
Holding torque of motor (N·m)0.0785
Brand and model number of stepping driver (optional)Moons, SR2
Type of plug for stageDB9(pin)
Type of cable for stageHigh flexibility cable (Helukabel, Germany)
Length of connection cable(m)0.2
Position-limit sensors (built-in), for each axis2*GP1S09xHCPI(Japan SHARP)
Origin-point sensors (built-in), for each axis1*GP1S09xHCPI(Japan SHARP)
Voltage of power supply for sensors (V)DC5~24V±10%
Control outputNPN open controller output. DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA)
Status of output portsOutput ON when sensor is blocked
Vertical direction(Kg)4
Travel range ( mm )X axis:50 Y axis:50
Stage surface size(mm)125×125
Central light-through hole dimension (mm)60×64
Light-through dimension at extreme position (mm)35×47
Transmission mechanismprecision ball screw,φ6×1
Guides(guiding mechanism)crossed-roller bearing guides
Main body material and surface treatmentBlack anodized aluminum alloy
Shaft coupling (external diameter- diameter of aperture 1-diameter of aperture 2) (mm)13/3/5
Weight(Kg)2.2
Resolution (step/half-step) (µm)5/2.5
20-fine-subdivision resolution (µm)0.25
Max speed(mm/s)*10
Repositioning accuracy (um)≤±1.5
Backlash(um)≤3
Static parallelism (mm)≤0.1
Motion straightness(um/100mm)≤10
Motional parallelism (um)≤25
Error on orthogonality (um)≤15
Brand and model number of motorShinano,STP-28D1003-08
Working current(A)1.3
Holding torque of motor (N·m)0.0785
Brand and model number of stepping driver (optional)Moons, SR2
Type of plug for stageDB9(pin)
Type of cable for stageHigh flexibility cable (Helukabel, Germany)
Length of connection cable(m)0.2
Position-limit sensors (built-in), for each axis2*GP1S09xHCPI(Japan SHARP)
Origin-point sensors (built-in), for each axis1*GP1S09xHCPI(Japan SHARP)
Voltage of power supply for sensors (V)DC5~24V±10%
Control outputNPN open controller output. DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA)
Status of output portsOutput ON when sensor is blocked
Vertical direction(Kg)4

Application context

Why this design is used

Application guidance is derived from the product family and tied to the model-specific selection fields above.

Automated scanning and mapping

Step-and-acquire across areas far wider than a single field of view.

Repeatable production indexing

Move parts between fixed stations with closed-loop encoders holding position over long shifts.

Programmable multi-axis motion

Coordinate several axes from software for processing, inspection and test sequences.

System integration

Integration and compatibility

Use these checks to connect XY5050 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Travel and resolution
Travel range ( mm ): X axis:50 Y axis:50 · Resolution (step/half-step) (µm): 5/2.5
Separate travel from resolution and both from repeatability. Repeatability is what an automated sequence actually depends on, and it is the figure most often absent from a headline specification.
Drive and feedback
Brand and model number of motor: Shinano,STP-28D1003-08 · Holding torque of motor (N·m): 0.0785
Pair open-loop mechanics with the specified high-voltage or inertial driver, and closed-loop variants with the controller their capacitive, strain-gauge or encoder feedback requires. Matching connectors do not guarantee electrical compatibility.
Load and mounting
Central light-through hole dimension (mm): 60×64 · Central light-through hole dimension (mm): 60×64
Check the load rating in the orientation you will use it — a vertical or cantilevered load is a moment, not a mass — and match the base to an M6 pattern on a 25 mm grid or a 1/4"-20 pattern on a 1 inch grid.

Technical FAQ

Integration questions for XY5050

What travel and resolution does the XY5050 provide?

Travel range ( mm ): X axis:50 Y axis:50 · Resolution (step/half-step) (µm): 5/2.5. Separate travel from resolution and both from repeatability. Repeatability is what an automated sequence actually depends on, and it is the figure most often absent from a headline specification.

Which controller does the XY5050 require?

Brand and model number of motor: Shinano,STP-28D1003-08 · Holding torque of motor (N·m): 0.0785. Pair open-loop mechanics with the specified high-voltage or inertial driver, and closed-loop variants with the controller their capacitive, strain-gauge or encoder feedback requires. Matching connectors do not guarantee electrical compatibility.

What load can the XY5050 carry, and how does it mount?

Central light-through hole dimension (mm): 60×64 · Central light-through hole dimension (mm): 60×64. Check the load rating in the orientation you will use it — a vertical or cantilevered load is a moment, not a mass — and match the base to an M6 pattern on a 25 mm grid or a 1/4"-20 pattern on a 1 inch grid.

Model selection

Nearby series comparison

Compare XY5050 with the closest available models in the Motorized XY Series All-In-One Two-Axis Stages family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterXY5050 (current)XY120120
Travel / adjustmentX axis:50 Y axis:50X axis:120 Y axis:120
Resolution / sensitivity5/2.520/10
Load / optic size13/3/520/5/10
Mounting interface60×64188×188