Lasers · Laser applications
Fluorescence and up-conversion
- 405-980 nm common excitation, including 808 and 980 nm high-power options | CW or modulated | Fluorescence systems need matched excitation lines, fiber delivery, stable intensity, and detector-aware source selection. | Ask for fluorophore, excitation and emission windows, power at sample, fiber/probe geometry, and detector range. | cw-dpss-diode | spectrum-measurement | application-systems
Product range
Where Fluorescence and up-conversion fits
- Category: Lasers
- Family: Laser applications
Specifications
Full specifications for this product are available on request. Contact us for the datasheet.
Related products
3D scanning & dimensional inspection
Select a listed wavelength from 375–1550 nm to match the surface and camera | CW line projection with TTL or analog modulation | A camera observes the projected line across the surface to measure shape, height, flatness and dimensions with a calibrated triangulation geometry. | Specify field width, working distance, depth range, smallest feature, scan speed, surface finish, camera response and required line width. | cw-dpss-diode
Weld seam tracking & positioning
Visible or near-infrared line projection, selected around process background and camera response | CW or camera-synchronized modulation | The projected line reveals joint edges and height changes so a vision system can estimate the seam position before or beside the welding process. | Specify joint geometry, working distance, camera view, welding background, line width, exposure timing, robot interface and protective-window arrangement. | cw-dpss-diode
Road, rail & tunnel inspection
Visible and infrared options selected for surface return and detector sensitivity | CW structured line with synchronized acquisition | A projected reference line supports profile measurements and alignment checks on roads, rails and tunnel surfaces as part of a calibrated inspection system. | Specify standoff, profile width, vehicle speed, sampling interval, vibration, ambient light, temperature and the required enclosure. | cw-dpss-diode
Semiconductor wafer inspection
UV and visible surface excitation; SWIR for suitable transmitting silicon stacks | CW scanning or pulsed excitation matched to the measurement | Useful defect contrast depends on the wafer stack, illumination geometry, collection optics and detector as well as the laser wavelength. | Specify wafer material and layer stack, defect classes and references, measurement method, excitation and detection bands, delivered dose, scan timing, repeatability and acceptance criteria. | cw-dpss-diode | ultrafast | fiber-lasers