Back to Home
TBR60N Motorized Rotation Stage

Zolix · Motorized Stages

TBR60N Motorized Rotation Stage

Motorized rotation stage with 360° rotation, a φ60 mm table and a φ8 H7 centre bore. Transmission: worm gear and worm, 110:1; guide: crossed-roller ring. Repositioning accuracy ≤±0.01°; max speed 32.7°/s. Horizontal load capacity 5 kg; weight 0.8 kg.

Repositioning accuracy
≤±0.01°
Horizontal load capacity
5 kg
Angle range
360°
Table diameter
φ60 mm
View quote list
TBR Series Motorized Rotation Stages

Specifications

Mechanical

Angle range (°)360
Table diameter (mm)φ60
Centre bore (mm)φ8 H7
Transmission mechanismWorm gear and worm
Worm gear ratio110:1
Worm gear materialDurable tin bronze worm gear
Worm material and treatmentSteel, high frequency quenched
Guide mechanismCrossed-roller ring
Body material and finishBlack anodized aluminum alloy
Weight (kg)0.8
Shaft coupling, OD-bore-bore (mm)19-4-5

Accuracy

Resolution, full/half step (°)≈0.016/0.008
Max speed (°/s)32.7
Repositioning accuracy (°)≤±0.01
Backlash (°)≤0.05
Static parallelism (mm)≤0.1
Static clearance (µm)≤26
Axial runout (µm)≤40
Radial runout (µm)≤25

Motor & electrical

Motor brandShinano (28 stepping motor)
Motor modelSTP- 28D3003-1210, two-phase
Step angle (°)1.8
Insulation resistanceOver 100 MΩ/min
Insulation strength500 V AC for 1 minute, no abnormality
Insulation classClass B
Motor weight (kg)0.11
Motor voltage (V)2.93
Motor current (A/phase)1.3
Resistance (Ω/phase)2.25±10%
Inductance (mH/phase)1.25
Motor holding torque (N·m)0.156
Braking torque (N·m)0.0032 (reference value)
Rotor inertia (g·cm²)17
Operating temperature (°C)0~+50
Max motor temperature (°C)80
Stepper driver (optional)Moons, SR2

Sensors & connection

ConnectorDB9 (pin)
Cable typeHigh flexibility cable
Cable length (m)0.2
Limit sensors (built-in)None
Origin sensor (built-in)1×GP1S09xHCPI (SHARP, Japan)
Sensor supply voltageDC5-24V±10%
Sensor current consumption (mA)<60 (total)
Sensor outputNMOS open leakage electrode outputDC5-24V 8mA or less.
Sensor output logicDC5~24V 50mA or less

Load capacity

Horizontal load capacity (kg)5
Vertical load capacity (kg)2
Inverted load capacity (kg)5

Compatible controllers

For the two-phase 28 stepping motor this stage uses.