Back to Home
PA200-C Motorized Linear Stage

PA200 base stage shown; the requested motor or cover option is not illustrated.

View full-size image

Motorized Stages

PA200-C Motorized Linear Stage

  • Travel range: 200 mm
  • Repositioning accuracy: ≤±3 µm
  • Horizontal load capacity: 30 kg
  • Table size: 120×120 mm
View quote list
PA Series Precise Motorized Linear Stages

Specifications

Mechanical

Travel range (mm)200
Table size (mm)120×120
Transmission mechanismPrecision ball screw φ12×4
Guide mechanismLinear-slider guides
Body material and finishBlack anodized aluminum alloy
Shaft coupling, OD-bore-bore (mm)30-6.35-8

Accuracy

Resolution, full step (µm)20
Resolution, 20× microstep (µm)1
Max speed (mm/s)40
Single-direction positioning accuracy (µm)≤30
Repositioning accuracy (µm)≤±3
Static clearance (µm)≤3
Backlash (µm)≤5
Static parallelism (mm)≤0.1
Dynamic straightness (µm)≤20
Dynamic parallelism (µm)≤25
Yaw (arcsec)≤50
Pitch (arcsec)≤55
Minimum incremental motion (µm)≤2

Motor & electrical

Motor and step angle (°)Two-phase 57 stepping motor, 1.8
Motor modelShinano, SST59D3206
Motor current (A)2.8
Motor holding torque (N·m)1.44
Stepper driver (optional)Moons, SR4

Sensors & connection

ConnectorDB9 (pin)
Cable typeHigh flexibility cable (Helukabel, Germany)
Cable length (m)0.2
Limit sensors (built-in)2×PM-L25 (SUNX, Japan)
Origin sensor (built-in)1×PM-L25 (SUNX, Japan)
Sensor supply voltageDC5~24V±10%
Sensor current consumption (mA)<60 (total)
Sensor outputNPN open-collector output DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA)
Sensor output logicPosition limit sensor: output ON when sensor is blocked;Origin-point sensor: output OFF when sensor is blocked;

Load capacity

Horizontal load capacity (kg)30
Vertical load capacity (kg)Please use "xx-Z" model for vertical load, refer to PAxx-Z series for details
Inverted load capacity (kg)15

Downloads

Product comparison

Compare with Thorlabs LTS300C/M

PA200-C and Thorlabs LTS300C/M offer options for motorized single-axis linear positioning. Compare the listed dimensions and interfaces for your setup.

Reference configuration: Precision-ground lead screw with linear guide system; exact bearing type not specified in reviewed table; Integrated two-phase stepper motor, 1.8°, 0.85 A/phase.

Published specifications for PA200-C and Thorlabs LTS300C/M
FeatureAvailable from PrecisometerPA200-CComparison referenceThorlabs LTS300C/M
Translation axesOne linear axisOne linear axis
Travel range200 mm300 mm
Guide mechanismLinear-slider guidesLinear guide system; exact bearing type not specified in reviewed table
Transmission mechanismPrecision ball screw φ12×4Precision-ground lead screw
Motor packageTwo-phase 57 stepping motor, 1.8° step angleIntegrated two-phase stepper motor, 1.8°, 0.85 A/phase
Position feedbackNo position-feedback specification in this exact configuration row; a motor encoder or linear encoder is not assumedFactory calibration files; no linear encoder specified
Moving platform / mounting120×120 mm; compare exact model drawing for tapped-hole patternSixteen M6 taps on 25.0 mm centers
Maximum speed40 mm/s; published condition applies50 mm/s maximum horizontal with lighter loads; reduce for heavier loads
Horizontal load capacity30 kg<12 kg recommended horizontal; 15 kg max horizontal; 4 kg max vertical
Published repeat-positioning measureRepositioning accuracy (direction not stated): ≤±3 µmBidirectional repeatability: <±2 µm
Published positioning-accuracy measureSingle-direction positioning accuracy: ≤30 µmCalibrated on-axis accuracy: <±5 µm; requires unit-specific calibration files
Backlash≤5 µm2 µm
Minimum incremental movement≤2 µmMinimum achievable: 0.1 µm; minimum repeatable: 4 µm
Controller / driver requirementsOptional stepper driver: Moons, SR4; electrical compatibility with Thorlabs controllers is not establishedIntegrated controller and power supply included; keypad or USB control; calibration via Kinesis/XA

Similar application. Check the interfaces for your setup.

Travel differs: 200 mm versus 300 mm; the reference does not reproduce the Precisometer travel range. The Precisometer ball screw differs from the Thorlabs lead-screw design, and the mounting, load and control package require separate review. The Precisometer -C option is a stainless-steel dust cover; the same protection option is not established for the reference. Published repositioning accuracy, unidirectional/bidirectional repeatability, encoder resolution, theoretical microstep size and absolute/calibrated accuracy describe different tests and must not be treated as equal performance. No drop-in mechanical, cable, controller or software compatibility is claimed. This comparison covers the listed features and does not establish interchangeability or identical performance.

Comparison references: PA200-C catalogue specifications and Thorlabs LTS300C/M published specifications. Checked 20 October 2026. Thorlabs is a trademark of its respective owner. Precisometer is not affiliated with or endorsed by Thorlabs.

All Thorlabs part-number comparisons →

Controllers for PA200-C

For the two-phase 57 stepping motor this stage uses.