Back to Home
KA600 Motorized Linear Stage
View full-size image

Motorized Stages

KA600 Motorized Linear Stage

  • Travel range: 600 mm
  • Unidirectional repeatability: ≤±5 µm
  • Horizontal load capacity: 80 kg
  • Table size: 200×200 mm
View quote list
KA Series Precision Closed-Loop Motorized Stage

Specifications

Mechanical

Travel range (mm)600
Table size (mm)200×200
Transmission mechanismPrecision ball screw φ25×5
Guide mechanismLinear-slider guides
Body material and finishBlack anodized aluminum alloy
Weight (kg)22.3
Shaft coupling, OD-bore-bore (mm)34-8-12

Accuracy

Closed-loop resolution (µm)0.5
Resolution, 20× microstep (µm)1.25
Max speed (mm/s)50
Single-direction positioning accuracy (µm)≤70
Unidirectional repeatability (µm)≤±5
Static clearance (µm)≤3
Backlash (µm)≤5
Static parallelism (mm)≤0.12
Dynamic straightness (µm)≤15/100mm
Dynamic parallelism (µm)≤15/100mm
Grating rulerLAMOTION
Minimum incremental motion (µm)≤1

Motor & electrical

Motor and step angle (°)Two-phase 57 stepping motor, 1.8
Motor modelShinano, SST59D5301
Motor current (A)3.0
Motor holding torque (N·m)1.57
Stepper driver (optional)Moons, SR4

Sensors & connection

ConnectorDB9 (pin)
Cable typeHigh flexibility cable (Helukabel, Germany)
Cable length (m)0.2
Limit sensors (built-in)2×PM-L25 (SUNX, Japan)
Origin sensor (built-in)1×PM-L25 (SUNX, Japan)
Sensor supply voltageDC5~24V±10%
Sensor current consumption (mA)<60 (total)
Sensor outputNPN open-collector output DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA)
Sensor output logicPosition limit sensor: output ON when sensor is blocked; Origin-point sensor: output OFF when sensor is blocked;

Load capacity

Horizontal load capacity (kg)80
Vertical load capacity (kg)Please use "xx-Z" model for vertical load, refer to KAxx-Z series for details
Inverted load capacity (kg)40

Downloads

Product comparison

Compare with Thorlabs LTS600C/M

KA600 and Thorlabs LTS600C/M offer options for motorized single-axis linear positioning. Compare the listed dimensions and interfaces for your setup.

Reference configuration: Precision-ground lead screw with linear guide system; exact bearing type not specified in reviewed table; Integrated two-phase stepper motor, 1.8°, 0.85 A/phase.

Published specifications for KA600 and Thorlabs LTS600C/M
FeatureAvailable from PrecisometerKA600Comparison referenceThorlabs LTS600C/M
Translation axesOne linear axisOne linear axis
Travel range600 mm600 mm
Guide mechanismLinear-slider guidesLinear guide system; exact bearing type not specified in reviewed table
Transmission mechanismPrecision ball screw φ25×5Precision-ground lead screw
Motor packageTwo-phase 57 stepping motor, 1.8° step angleIntegrated two-phase stepper motor, 1.8°, 0.85 A/phase
Position feedbackLAMOTION; published closed-loop resolution 0.5 µmFactory calibration files; no linear encoder specified
Moving platform / mounting200×200 mm; compare exact model drawing for tapped-hole patternSixteen M6 taps on 25.0 mm centers
Maximum speed50 mm/s; published condition applies35 mm/s maximum horizontal with lighter loads; reduce for heavier loads
Horizontal load capacity80 kg<12 kg recommended horizontal; 15 kg max horizontal; 4 kg max vertical
Published repeat-positioning measureUnidirectional repeatability: ≤±5 µmBidirectional repeatability: <±2 µm
Published positioning-accuracy measureSingle-direction positioning accuracy: ≤70 µmCalibrated on-axis accuracy: <±5 µm; requires unit-specific calibration files
Backlash≤5 µm2 µm
Minimum incremental movement≤1 µmMinimum achievable: 0.1 µm; minimum repeatable: 4 µm
Controller / driver requirementsOptional stepper driver: Moons, SR4; electrical compatibility with Thorlabs controllers is not establishedIntegrated controller and power supply included; keypad or USB control; calibration via Kinesis/XA

Similar application. Check the interfaces for your setup.

Both specify 600 mm travel on one linear axis. The Precisometer ball screw differs from the Thorlabs lead-screw design, and the mounting, load and control package require separate review. Precisometer publishes Fagor linear-scale closed-loop feedback; the selected Thorlabs NRT/LTS reference does not specify that equivalent linear-scale feedback package. Published repositioning accuracy, unidirectional/bidirectional repeatability, encoder resolution, theoretical microstep size and absolute/calibrated accuracy describe different tests and must not be treated as equal performance. No drop-in mechanical, cable, controller or software compatibility is claimed. This comparison covers the listed features and does not establish interchangeability or identical performance.

Comparison references: KA600 catalogue specifications and Thorlabs LTS600C/M published specifications. Checked 20 October 2026. Thorlabs is a trademark of its respective owner. Precisometer is not affiliated with or endorsed by Thorlabs.

All Thorlabs part-number comparisons →

Controllers for KA600