Back to Home
KA100 Motorized Linear Stage
View full-size image

Motorized Stages

KA100 Motorized Linear Stage

  • Travel range: 100 mm
  • Unidirectional repeatability: ≤±3 µm
  • Horizontal load capacity: 30 kg
  • Table size: 120×120 mm
View quote list
KA Series Precision Closed-Loop Motorized Stage

Specifications

Mechanical

Travel range (mm)100
Table size (mm)120×120
Transmission mechanismPrecision ball screw φ12×4
Guide mechanismLinear-slider guides
Body material and finishBlack anodized aluminum alloy
Weight (kg)6.8
Shaft coupling, OD-bore-bore (mm)30-6.35-8

Accuracy

Closed-loop resolution (µm)1
Resolution, 20× microstep (µm)1
Max speed (mm/s)40
Single-direction positioning accuracy (µm)≤30
Unidirectional repeatability (µm)≤±3
Static clearance (µm)≤3
Backlash (µm)≤5
Static parallelism (mm)≤0.1
Dynamic straightness (µm)≤10
Dynamic parallelism (µm)≤15
Yaw (arcsec)≤30
Pitch (arcsec)≤35
Grating rulerFagor, MX or MKX series
Minimum incremental motion (µm)≤1

Motor & electrical

Motor and step angle (°)Two-phase 57 stepping motor, 1.8
Motor modelShinano, SST59D3206
Motor current (A)2.8
Motor holding torque (N·m)1.44
Stepper driver (optional)Moons, SR4

Sensors & connection

ConnectorDB9 (pin)
Cable typeHigh flexibility cable (Helukabel, Germany)
Cable length (m)0.2
Limit sensors (built-in)2×PM-L25 (SUNX, Japan)
Origin sensor (built-in)1×PM-L25 (SUNX, Japan)
Sensor supply voltageDC5~24V±10%
Sensor current consumption (mA)<60 (total)
Sensor outputNPN open-collector output DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA)
Sensor output logicPosition limit sensor: output ON when sensor is blocked; Origin-point sensor: output OFF when sensor is blocked;

Load capacity

Horizontal load capacity (kg)30
Vertical load capacity (kg)Please use "xx-Z" model for vertical load, refer to KAxx-Z series for details
Inverted load capacity (kg)15

Downloads

Product comparison

Compare with Thorlabs NRT100/M

KA100 and Thorlabs NRT100/M offer options for motorized single-axis linear positioning. Compare the listed dimensions and interfaces for your setup.

Reference configuration: Trapezoidal lead screw with four recirculating-ball carrier bearings on linear guide rails; Two-phase stepper motor; 409,600 microsteps/revolution.

Published specifications for KA100 and Thorlabs NRT100/M
FeatureAvailable from PrecisometerKA100Comparison referenceThorlabs NRT100/M
Translation axesOne linear axisOne linear axis
Travel range100 mm100 mm
Guide mechanismLinear-slider guidesFour recirculating-ball carrier bearings on linear guide rails
Transmission mechanismPrecision ball screw φ12×4Trapezoidal lead screw
Motor packageTwo-phase 57 stepping motor, 1.8° step angleTwo-phase stepper motor; 409,600 microsteps/revolution
Position feedbackFagor, MX or MKX series; published closed-loop resolution 1 µmNo linear encoder specified
Moving platform / mounting120×120 mm; compare exact model drawing for tapped-hole patternEight M6 taps on 25.0 mm centers
Maximum speed40 mm/s; published condition applies30 mm/s with light loads; reduce at higher load
Horizontal load capacity30 kg<12 kg recommended horizontal; 20 kg max horizontal; 5 kg max vertical
Published repeat-positioning measureUnidirectional repeatability: ≤±3 µmBidirectional repeatability: 1.0 µm
Published positioning-accuracy measureSingle-direction positioning accuracy: ≤30 µmCalibrated absolute on-axis accuracy: 2.0 µm typical, 5.0 µm max; requires supplied calibration files
Backlash≤5 µm<3 µm
Minimum incremental movement≤1 µmMinimum achievable: 0.10 µm; minimum repeatable: 2 µm
Controller / driver requirementsOptional stepper driver: Moons, SR4; electrical compatibility with Thorlabs controllers is not establishedUMC universal controller sold separately; direct connection and XA software. Existing compatible BSC controllers require an adapter and support Kinesis/XA

Similar application. Check the interfaces for your setup.

Both specify 100 mm travel on one linear axis. The Precisometer ball screw differs from the Thorlabs lead-screw design, and the mounting, load and control package require separate review. Precisometer publishes Fagor linear-scale closed-loop feedback; the selected Thorlabs NRT/LTS reference does not specify that equivalent linear-scale feedback package. Published repositioning accuracy, unidirectional/bidirectional repeatability, encoder resolution, theoretical microstep size and absolute/calibrated accuracy describe different tests and must not be treated as equal performance. No drop-in mechanical, cable, controller or software compatibility is claimed. This comparison covers the listed features and does not establish interchangeability or identical performance.

Comparison references: KA100 catalogue specifications and Thorlabs NRT100/M published specifications. Checked 20 October 2026. Thorlabs is a trademark of its respective owner. Precisometer is not affiliated with or endorsed by Thorlabs.

All Thorlabs part-number comparisons →

Controllers for KA100

For the two-phase 57 stepping motor this stage uses.