CXPF30-80-ASP1 Motorized Linear Stage

CXPF30-80 base stage shown; the requested motor or cover option is not illustrated.

View full-size image

Motorized Stages

CXPF30-80-ASP1 Motorized Linear Stage

  • Travel range: 30 mm
  • Repositioning accuracy: ≤±1.5 µm
  • Horizontal load capacity: 16 kg
  • Table size: 80×80 mm
View quote list
CXPF Series High-Precise Motorized Linear Stages

Specifications

Mechanical

Travel range (mm)30
Table size (mm)80×80
Transmission mechanismBall screw φ8×2
Guide mechanismCrossed-roller bearing guides
Body material and finishBlack anodized aluminum-alloy

Accuracy

Repositioning accuracy (µm)≤±1.5
Backlash (µm)≤3
Static parallelism (mm)≤0.08
Dynamic straightness (µm)≤10
Dynamic parallelism (µm)≤15

Sensors & connection

Limit sensors (built-in)2×GP1S09xHCP (SHARP, Japan)
Origin sensor (built-in)1×GP1S09xHCPI (SHARP, Japan)
Sensor supply voltageDC5-24V±10%
Sensor outputNPN open-collector output DC5~24V 8mA or less Residual voltage 0.3V or less (when load current is 2mA)
Sensor output logicOutput ON when sensor is blocked

Load capacity

Horizontal load capacity (kg)16
Vertical load capacity (kg)5
Inverted load capacity (kg)5

Construction details

  • Guidance assembly: Crossed-roller bearing guides.
  • Drive assembly: Ball screw φ8×2.
Product datasheet (PDF)

Downloads

Product comparison

Compare with Thorlabs LNR25ZFS/M

CXPF30-80-ASP1 and Thorlabs LNR25ZFS/M offer options for motorized single-axis linear positioning. Compare the listed dimensions and interfaces for your setup.

Reference configuration: ZFS25B geared screw actuator with crossed-roller bearings; Dual-phase stepper motor, 400:9 gear reduction.

Published specifications for CXPF30-80-ASP1 and Thorlabs LNR25ZFS/M
FeatureAvailable from PrecisometerCXPF30-80-ASP1Comparison referenceThorlabs LNR25ZFS/M
Translation axesOne linear axisOne linear axis
Travel range30 mm25 mm
Guide mechanismCrossed-roller bearing guidesCrossed-roller bearings
Transmission mechanismBall screw φ8×2ZFS25B geared screw actuator
Motor packageExact motor/drive package is not established in the reviewed configuration row; confirm the ordered motor and controllerDual-phase stepper motor, 400:9 gear reduction
Position feedbackNo position-feedback specification in this exact configuration row; a motor encoder or linear encoder is not assumedNo linear encoder specified
Moving platform / mounting80×80 mm; compare exact model drawing for tapped-hole patternCompare reference mechanical drawing; matching platform size and hole pattern not established
Horizontal load capacity16 kg5 kg horizontal; 0.5 kg vertical
Published repeat-positioning measureRepositioning accuracy (direction not stated): ≤±1.5 µmBidirectional repeatability: 3.0 µm
Backlash≤3 µmNot specified in reviewed source
Reference minimum movement / resolutionMeasured minimum incremental movement omitted for this exact motor option; no base-motor value assumedCalculated travel per microstep: 0.46 nm; theoretical, not measured stage accuracy
Controller / driver requirementsA controller/driver matched to this exact ordered motor is required; package and pinout must be confirmed; electrical compatibility with Thorlabs controllers is not establishedKST201 stepper controller and compatible power supply sold separately; Thorlabs benchtop stepper controllers cannot drive this stage

Similar application. Check the interfaces for your setup.

Travel differs: 30 mm versus 25 mm; the reference does not reproduce the Precisometer travel range. The Precisometer screw/guide and platform design differs from the Thorlabs crossed-roller stage and its screw actuator; matching travel does not establish equal mechanics or mounting. The exact motor option has no complete motor/feedback/driver specification in the reviewed row. Only the mechanical values actually published for this configuration are used; base-motor speed, step resolution and incremental-motion values are not transferred. Published repositioning accuracy, unidirectional/bidirectional repeatability, encoder resolution, theoretical microstep size and absolute/calibrated accuracy describe different tests and must not be treated as equal performance. No drop-in mechanical, cable, controller or software compatibility is claimed. This comparison covers the listed features and does not establish interchangeability or identical performance.

Comparison references: CXPF30-80-ASP1 catalogue specifications and Thorlabs LNR25ZFS/M published specifications. Checked 20 October 2026. Thorlabs is a trademark of its respective owner. Precisometer is not affiliated with or endorsed by Thorlabs.

All Thorlabs part-number comparisons →