TUN-TiA-393-408: Marking depends on how optical energy is delivered to the target; 405 nm emission governs absorption, while the listed temporal parameter (10~50 kHz) governs peak intensity and heat deposition.
Pulse energy, repetition rate, pulse width
TUN-TiA-393-408 is a 405 nm Pulsed laser. Used for marking, carving, measure, scientific research. Key specifications: output / average power 1~1000 mW, repetition rate 10~50 kHz, pulse width ~35 ns @50 kHz. View specifications, datasheet and enquiry options from Precisometer.
Specifications
11 specification rows
| Wavelength | 405 nm |
|---|---|
| Output / average power | 1~1000 mW |
| Repetition rate | 10~50 kHz |
| Pulse width | ~35 ns @50 kHz |
| Operating mode | Actively Q-switched |
| Ave power stability (rms, 4 hours±3℃) | <5%, <3% |
| Beam divergence, full angle (mrad) | <4 |
| Warm-up time (minutes) | <10 |
| Cooled method | Air Cooled |
| Operating temperature (℃) | 15-35 |
| Power supply (100-240VAC) | PSU-AOM (3U) |
| Expected lifetime (hours) | >10000 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
TUN-TiA-393-408: Marking depends on how optical energy is delivered to the target; 405 nm emission governs absorption, while the listed temporal parameter (10~50 kHz) governs peak intensity and heat deposition.
TUN-TiA-393-408: 405 nm emission determines compatible optics, coatings and detectors for Carving. The catalogued beam parameter (<4) helps predict how the source will focus and propagate through the instrument.
TUN-TiA-393-408: Measure benefits from a stable, focusable source. 405 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<4) informs waist size and propagation.
TUN-TiA-393-408: 405 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (<4) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect TUN-TiA-393-408 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Air Cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam divergence, full angle (mrad): <4. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare TUN-TiA-393-408 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | TUN-TiA-393-408 (current) | MDL-NS-405 | MDL-PS-405 |
|---|---|---|---|
| Wavelength | 405 nm | 405 nm | 405 nm |
| Optical power / pulse energy | 1~1000 mW | 1~300 mW | 1~100 mW |
| Operating mode / pulse width | 10~50 kHz | 10 ns~10 ms | 0.1~80 MHz |
| Beam quality | <4 | Multimode | Multimode |
Compare the TUN-TiA-393-408 with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide