Back to Home

Pulse energy, repetition rate, pulse width

TUN-TiA-393-408405 nm violet tunable Q-switched pulsed laser

405 nm

TUN-TiA-393-408 is a 405 nm Pulsed laser. Used for marking, carving, measure, scientific research. Key specifications: output / average power 1~1000 mW, repetition rate 10~50 kHz, pulse width ~35 ns @50 kHz. View specifications, datasheet and enquiry options from Precisometer.

Specifications

TUN-TiA-393-408

11 specification rows

Wavelength405 nm
Output / average power1~1000 mW
Repetition rate10~50 kHz
Pulse width~35 ns @50 kHz
Operating modeActively Q-switched
Ave power stability (rms, 4 hours±3℃)<5%, <3%
Beam divergence, full angle (mrad)<4
Warm-up time (minutes)<10
Cooled methodAir Cooled
Operating temperature (℃)15-35
Power supply (100-240VAC)PSU-AOM (3U)
Expected lifetime (hours)>10000

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Marking

TUN-TiA-393-408: Marking depends on how optical energy is delivered to the target; 405 nm emission governs absorption, while the listed temporal parameter (10~50 kHz) governs peak intensity and heat deposition.

Carving

TUN-TiA-393-408: 405 nm emission determines compatible optics, coatings and detectors for Carving. The catalogued beam parameter (<4) helps predict how the source will focus and propagate through the instrument.

Measure

TUN-TiA-393-408: Measure benefits from a stable, focusable source. 405 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<4) informs waist size and propagation.

Scientific research

TUN-TiA-393-408: 405 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (<4) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect TUN-TiA-393-408 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air Cooled · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <4
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for TUN-TiA-393-408

What cooling does the TUN-TiA-393-408 require?

Cooled method: Air Cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the TUN-TiA-393-408 deliver?

Beam divergence, full angle (mrad): <4. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare TUN-TiA-393-408 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterTUN-TiA-393-408 (current)MDL-NS-405MDL-PS-405
Wavelength405 nm405 nm405 nm
Optical power / pulse energy1~1000 mW1~300 mW1~100 mW
Operating mode / pulse width10~50 kHz10 ns~10 ms0.1~80 MHz
Beam quality<4MultimodeMultimode