Q-switched Laser457 nm blue Q-switched pulsed laser

457 nm

Q-switched Laser is a 457 nm Pulsed laser. Used for medical imaging, flow cytometry, dna sequencing, marking. Key specifications: output / average power 1-15 uJ/ 1-150 mW, features Actively. View specifications, datasheet and enquiry options from Precisometer.

Specifications

Q-switched Laser

3 specification rows

Wavelength457 nm
Output / average power1-15 uJ/ 1-150 mW
Beam / notesSeries: Q-switched Laser; Features: Actively
FeaturesActively

Series-level technical context

Engineering context for a thin Pulsed Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near pulsed lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1-15 uJ/ 1-150 mW
  • Output / average power: 1~80 mW
  • Output / average power: 1~60 mW
  • Operating mode: Actively Q-switched
  • Operating mode: Pulsed

Beam-quality tolerance context

Nearby series records state M²: <2, M²: <1.5, Beam divergence, full angle (mrad): <3, and Beam divergence, full angle (mrad): <1. These are series context, not guaranteed values for Q-switched Laser; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Pump and pulsed laser head
  2. Step 2Safety shutter and optional isolator
  3. Step 3Beam-expansion or focusing optics
  4. Step 4Sample with synchronized trigger or detector

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Medical imaging

Q-switched Laser: 457 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Flow cytometry

Q-switched Laser: 457 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

Q-switched Laser: 457 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Marking

Q-switched Laser: Marking depends on how optical energy is delivered to the target; 457 nm emission governs absorption, while pulse energy, duration and repetition rate governs peak intensity and heat deposition.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare Q-switched Laser with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterQ-switched Laser (current)EO-XS-457MDL-NS-450
Wavelength457 nm457 nm450 nm
Optical power / pulse energy1-15 uJ/ 1-150 mW1-15 uJ/ 1-150 mW1~80 mW
Operating mode / pulse widthConfirm for this modelActively Q-switchedPulsed
Beam qualityConfirm for this model<3Confirm for this model