MDL-NS-450 is a 450 nm Pulsed laser. Used for medical imaging, flow cytometry, dna sequencing, microelectronics. Pulse width 10 ns ~10 ms. Key specifications: operating mode Pulsed, output / average power 1~80 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MDL-NS-450

3 specification rows

Wavelength450 nm
Operating modePulsed
Output / average power1~80 mW
Beam / notesPulse width 10 ns~10 ms

Series-level technical context

Engineering context for a thin Pulsed Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near pulsed lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~60 mW
  • Output / average power: 1~80 mW
  • Average power: 1-600
  • Operating mode: Pulsed
  • Operating mode: Actively Q-switched

Beam-quality tolerance context

Nearby series records state M²: <2, M²: <1.5, Beam divergence, full angle (mrad): <1, and Beam divergence, full angle (mrad): <3. These are series context, not guaranteed values for MDL-NS-450; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Pump and pulsed laser head
  2. Step 2Safety shutter and optional isolator
  3. Step 3Beam-expansion or focusing optics
  4. Step 4Sample with synchronized trigger or detector

Application context

Why this design is used

Applications named on a datasheet for this product line, interpreted against this model’s listed wavelength and beam data.

Medical imaging

MDL-NS-450: 450 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Flow cytometry

MDL-NS-450: 450 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

MDL-NS-450: 450 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Microelectronics

MDL-NS-450: 450 nm emission determines compatible optics, coatings and detectors for Microelectronics. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MDL-NS-450 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMDL-NS-450 (current)MDL-PS-450MDL-NS-447
Wavelength450 nm450 nm447 nm
Optical power / pulse energy1~80 mW1~60 mW1~80 mW
Operating mode / pulse widthPulsedPulsedPulsed
Beam qualityConfirm for this model<1<1