Back to Home

Pulse energy, repetition rate, pulse width

MDL-PS-445445 nm violet pulsed laser

445 nm

MDL-PS-445 is a 445 nm Pulsed laser. Used for medical imaging, flow cytometry, dna sequencing. Pulse width 1 00~1000 ps MDL-PS-445/ 1~60mW Pulse width 1 00~1000 ps. Key specifications: operating mode Pulsed, output / average power 1~60 mW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MDL-PS-445

17 specification rows

Operating modePulsed
Output / average power1~60 mW
Beam / notesPulse width 100~1000 ps MDL-ps-445/ 1~60 mW Pulse width 100~1000 ps
Power stability (rms, 4 hours ± 3°C)<2%, <1%, <0.5%
M2<1.5 / <1.2
Beam divergence, full angle (mrad)<1
Warm-up time (minutes)<5
Cooled methodConduction
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-III-FDA/PSU-III-LED/PSU-A-D/PSU-III-OEM
Expected lifetime (hours)>10000
Central wavelength (nm)445±5
Output power (mW)1-500
Transverse modeNear TEM00
Polarization ratio>50:1, (>100:1 optional) Horizontal±5 degree (Vertical optional)
Beam height from base plate (mm)24.8
Modulation optionDC-1kHz, 1kHz-10kHz, 10kHz-30kHz, 30kHz-100kHz optional; TTL and Analog optional

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Medical imaging

MDL-PS-445: 445 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

MDL-PS-445: 445 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MDL-PS-445: 445 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MDL-PS-445 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Conduction · Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
M2: <1.5 / <1.2 · Beam divergence, full angle (mrad): <1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MDL-PS-445

What cooling does the MDL-PS-445 require?

Cooled method: Conduction · Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MDL-PS-445 deliver?

M2: <1.5 / <1.2 · Beam divergence, full angle (mrad): <1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MDL-PS-445 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMDL-PS-445 (current)MDL-NS-445MDL-NS-447
Wavelength445 nm445 nm447 nm
Optical power / pulse energy1~60 mW1~80 mW1~80 mW
Operating mode / pulse widthPulsedPulsedPulsed
Beam quality<1<1<1