Pulse energy, repetition rate, pulse width

PS-L-310310 nm UV pulsed laser

310 nm

PS-L-310 is a 310 nm Pulsed laser. Used for lidar, laser spectroscopy, sensing, metrology. Picosecond Pulsed UV Laser. Key specifications: output / average power 1~10 mW, all picosecond pulsed laser is made features of short pulse duration, high repetition rate and good beam, pulse duration(ps) <500. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PS-L-310

10 specification rows

Wavelength310 nm
Output / average power1~10 mW
Beam / notesPicosecond Pulsed UV Laser
All picosecond pulsed laseris made features of short pulse duration, high repetition rate and good beam
Pulse duration(ps)<500
Max average power (mW)1~10
Rep. rate (kHz)(optional)3
Ave power stability (over 4 hours)<5%, <3%
Warm-up time (minutes)<10
Operating temperature (°C)20~30
Expected lifetime (hours)10000

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Lidar

PS-L-310: Lidar depends on how optical energy is delivered to the target; 310 nm emission governs absorption, while the listed temporal parameter (<500) governs peak intensity and heat deposition.

Laser spectroscopy

PS-L-310: 310 nm emission sets the excitation and detector-band choice for Laser spectroscopy; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line.

Sensing

PS-L-310: 310 nm emission determines compatible optics, coatings and detectors for Sensing. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Metrology

PS-L-310: 310 nm emission determines compatible optics, coatings and detectors for Metrology. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

System integration

Integration and compatibility

Use these checks to connect PS-L-310 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (°C): 20~30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Technical FAQ

Integration questions for PS-L-310

What cooling does the PS-L-310 require?

Operating temperature (°C): 20~30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PS-L-310 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPS-L-310 (current)PS-M-310AO-U-320-DP
Wavelength310 nm310 nm320 nm
Optical power / pulse energy1~10 mW1~40 mW1~40 mW
Operating mode / pulse width<500Passively Q-switched1-30 kHz
Beam qualityConfirm for this modelConfirm for this model<2.0