Operating modeQ-switched
Output / average power1~10 mW
Pulse energy0.1~1 uJ
Beam / notesQ-switched UV Laser
Rep. rate (kHz)10
Power stability (rms, 4 hours±3℃)<5%, <3%
Cooled methodAir cooled
Operating temperature (℃)10-35
Power supply (100-240VAC)PSU-AOM (3U)
Wavelength (nm)305±2
Single pulse energy (µJ)0.1-1
Pulse duration (ns)~3
Peak power (kW)0.1-1
Warm-up time (minutes)<10
Beam divergence, full angle (mrad)<5
Beam diameter at the aperture (1/e2,mm)<5
Beam height from base plate (mm)82

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

EO-XS-305: 305 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (<5) helps predict how the source will focus and propagate through the instrument.

Laboratory measurement

EO-XS-305: Laboratory measurement benefits from a stable, focusable source. 305 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<5) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect EO-XS-305 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <5 · Beam diameter at the aperture (1/e2,mm): <5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for EO-XS-305

What cooling does the EO-XS-305 require?

Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the EO-XS-305 deliver?

Beam divergence, full angle (mrad): <5 · Beam diameter at the aperture (1/e2,mm): <5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare EO-XS-305 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterEO-XS-305 (current)AO-U-303-DPPS-L-310
Wavelength305 nm303 nm310 nm
Optical power / pulse energy1~10 mW1~3 mW1~10 mW
Operating mode / pulse widthQ-switchedQ-switched<500
Beam quality<5Near TEM00<10