Back to Home

Pulse energy, repetition rate, pulse width

AO-U-303-DP303 nm UV Q-switched pulsed laser

303 nm

AO-U-303-DP is a 303 nm Pulsed laser. Q-switched UV Laser. Key specifications: operating mode Q-switched, output / average power 1~3 mW, pulse energy 0.6 uJ. View specifications, datasheet and enquiry options from Precisometer.

Specifications

AO-U-303-DP

19 specification rows

Operating modeQ-switched
Output / average power1~3 mW
Pulse energy0.6 uJ
Beam / notesQ-switched UV Laser
Power stability (rms, 4 hours, ±3°C)<5%, <3%
Beam diameter at the aperture 1/e2 (mm)<2.0
Warm-up time (minutes)<10
Operating temperature (℃)10-35
Cooled methodWater cooled
Power supply (12VDC)12V/25A
Expected lifetime (hours)>10000
Wavelength (nm)303±1
Single pulse energy (μJ)0.6@5kHz
Pulse duration (ns)~18@5kHz
Peak power (kW)~0.1@5kHz
Rep. rate (kHz)1-30
Transverse modeNear TEM00
Beam divergence, full angle (mrad)<2.0
Beam height from base plate (mm)99.5

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

AO-U-303-DP: 303 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

Laboratory measurement

AO-U-303-DP: Laboratory measurement benefits from a stable, focusable source. 303 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (Near TEM00) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect AO-U-303-DP to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 10-35 · Cooled method: Water cooled
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam diameter at the aperture 1/e2 (mm): <2.0 · Transverse mode: Near TEM00
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for AO-U-303-DP

What cooling does the AO-U-303-DP require?

Operating temperature (℃): 10-35 · Cooled method: Water cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the AO-U-303-DP deliver?

Beam diameter at the aperture 1/e2 (mm): <2.0 · Transverse mode: Near TEM00. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare AO-U-303-DP with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterAO-U-303-DP (current)EO-XS-305AO-K-300
Wavelength303 nm305 nm300 nm
Optical power / pulse energy1~3 mW1~10 mW1~50 mW
Operating mode / pulse widthQ-switchedQ-switchedQ-switched
Beam qualityNear TEM00<5<1