Pulse energy, repetition rate, pulse width

PGL-V-H-655656 nm red Q-switched pulsed laser

656 nm

PGL-V-H-655 is a 656 nm Pulsed laser. Used for medical imaging, flow cytometry, dna sequencing, microelectronics. Q-switched Red Laser. Key specifications: operating mode Q-switched, output / average power 1~1000 mW, power stability(rms, over 4 hours) <5%, <3%, <1%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-V-H-655

15 specification rows

Wavelength656 nm
Operating modeQ-switched
Output / average power1~1000 mW
Beam / notesQ-switched Red Laser
Power stability(rms, over 4 hours)<5%, <3%, <1%
Transverse modeNear TEM00 / Multimode
Beam divergence, full angle (mrad)<1.5 / <3.5
Warm-up timeminutes / <10
Expected lifetime (hours)10000
Warranty (years)1
Operating voltage(PSU-V-OEM)100-240VAC
Connection9 pin connector
Operating temperature-10°C to 50°C
Storage temperature-20°C to 80°C
Humidity< 90%, non-condensing
Dimensions of laser head92(L)×40(W)×40(H)mm3

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Medical imaging

PGL-V-H-655: 656 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<5%, <3%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

PGL-V-H-655: 656 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<5%, <3%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

PGL-V-H-655: 656 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<5%, <3%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Microelectronics

PGL-V-H-655: 656 nm emission determines compatible optics, coatings and detectors for Microelectronics. The catalogued beam parameter (Near TEM00 / Multimode) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect PGL-V-H-655 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature: -10°C to 50°C
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 / Multimode · Beam divergence, full angle (mrad): <1.5 / <3.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Mechanical envelope
Dimensions of laser head: 92(L)×40(W)×40(H)mm3
Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Technical FAQ

Integration questions for PGL-V-H-655

What cooling does the PGL-V-H-655 require?

Operating temperature: -10°C to 50°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the PGL-V-H-655 deliver?

Transverse mode: Near TEM00 / Multimode · Beam divergence, full angle (mrad): <1.5 / <3.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

How is the PGL-V-H-655 mounted?

Dimensions of laser head: 92(L)×40(W)×40(H)mm3. Verify the housing drawing and bolt length before designing a mount. A laser head rarely carries a table thread itself, so the adapter between it and an M6 or 1/4"-20 grid is part of the specification.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-V-H-655 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-V-H-655 (current)PGL-D8-655PGL-D12-655
Wavelength656 nm656 nm656 nm
Optical power / pulse energy1~1000 mW1~50 mW1~100 mW
Operating mode / pulse widthQ-switchedQ-switchedQ-switched
Beam qualityNear TEM00 / MultimodeNear TEM00Near TEM00