Pulse energy, repetition rate, pulse width

PGL-D12-655656 nm red Q-switched pulsed laser

656 nm

PGL-D12-655 is a 656 nm Pulsed laser. Used for medical imaging, flow cytometry, dna sequencing, microelectronics. Q-switched Red Laser. Key specifications: operating mode Q-switched, output / average power 1~100 mW, transverse mode Near TEM00. View specifications, datasheet and enquiry options from Precisometer.

Specifications

PGL-D12-655

11 specification rows

Wavelength656 nm
Operating modeQ-switched
Output / average power1~100 mW
Beam / notesQ-switched Red Laser
Transverse modeNear TEM00
Beam divergence, full angle (mrad)<1
Expected lifetime (hours)10000
Operating voltage(external PCB1)3VDC
ConnectionCable with flying leads
Operating temperature0°C to 40°C
Storage temperature-20°C to 80°C
Humidity< 90%, non-condensing

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Medical imaging

PGL-D12-655: 656 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Flow cytometry

PGL-D12-655: 656 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

PGL-D12-655: 656 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Microelectronics

PGL-D12-655: 656 nm emission determines compatible optics, coatings and detectors for Microelectronics. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect PGL-D12-655 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature: 0°C to 40°C
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · Beam divergence, full angle (mrad): <1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for PGL-D12-655

What cooling does the PGL-D12-655 require?

Operating temperature: 0°C to 40°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the PGL-D12-655 deliver?

Transverse mode: Near TEM00 · Beam divergence, full angle (mrad): <1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare PGL-D12-655 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterPGL-D12-655 (current)PGL-D8-655PGL-LF-655
Wavelength656 nm656 nm656 nm
Optical power / pulse energy1~100 mW1~50 mW1~130 mW
Operating mode / pulse widthQ-switchedQ-switchedQ-switched
Beam qualityNear TEM00Near TEM00<1.5