Medical imaging
PGL-D8-655: 655 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
Pulse energy, repetition rate, pulse width
PGL-D8-655 is a 655 nm Pulsed laser. Used for medical imaging, flow cytometry, dna sequencing, microelectronics. Picosecond Pulsed Red Laser. Key specifications: operating mode Pulsed, output / average power 1~50 mW, transverse mode Near TEM00. View specifications, datasheet and enquiry options from Precisometer.
Specifications
11 specification rows
| Wavelength | 655 nm |
|---|---|
| Operating mode | Pulsed |
| Output / average power | 1~50 mW |
| Beam / notes | Picosecond Pulsed Red Laser |
| Transverse mode | Near TEM00 |
| Beam divergence, full angle (mrad) | <1 |
| Expected lifetime (hours) | 10000 |
| Operating voltage(external PCB1) | 3VDC |
| Connection | Cable with flying leads |
| Operating temperature | 0°C to 40°C |
| Storage temperature | -20°C to 80°C |
| Humidity | < 90%, non-condensing |
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
PGL-D8-655: 655 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
PGL-D8-655: 655 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
PGL-D8-655: 655 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
PGL-D8-655: 655 nm emission determines compatible optics, coatings and detectors for Microelectronics. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect PGL-D8-655 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Operating temperature: 0°C to 40°C. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Transverse mode: Near TEM00 · Beam divergence, full angle (mrad): <1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare PGL-D8-655 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | PGL-D8-655 (current) | MDL-NS-655 | MDL-PS-655 |
|---|---|---|---|
| Wavelength | 655 nm | 655 nm | 655 nm |
| Optical power / pulse energy | 1~50 mW | 1~180 mW | 1~50 mW |
| Operating mode / pulse width | Pulsed | Pulsed | Pulsed |
| Beam quality | Near TEM00 | <1.0 | <1.0 |
Compare the PGL-D8-655 with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide