Scientific research
MSL-AO-1064: 1064 nm emission determines compatible optics, coatings and detectors for Scientific research. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
Pulse energy, repetition rate, pulse width
MSL-AO-1064 is a 1064 nm Pulsed laser. Used for scientific research, physics experiment, medical imaging, flow cytometry. Key specifications: operating mode Q-switched, pulse energy 1~200 uJ, repetition rate 1 Hz~1 kHz. View specifications, datasheet and enquiry options from Precisometer.
Specifications
4 specification rows
| Wavelength | 1064 nm |
|---|---|
| Operating mode | Q-switched |
| Pulse energy | 1~200 uJ |
| Repetition rate | 1 Hz~1 kHz |
| Spectral linewidth | <10 MHz |
Series-level technical context
This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near pulsed lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.
Nearby series records state M²: <1.2, M²: <1.3, M²: <2, and Beam divergence, full angle (mrad): <1.0. These are series context, not guaranteed values for MSL-AO-1064; confirm them on the order-specific datasheet.
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
MSL-AO-1064: 1064 nm emission determines compatible optics, coatings and detectors for Scientific research. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
MSL-AO-1064: Physics experiment benefits from a stable, focusable source. 1064 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.
MSL-AO-1064: 1064 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
MSL-AO-1064: 1064 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MSL-AO-1064 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | MSL-AO-1064 (current) | FS-H- 10 64A | FS-H- 10 64B |
|---|---|---|---|
| Wavelength | 1064 nm | 1064 nm | 1064 nm |
| Optical power / pulse energy | 1~200 uJ | 1-500 mW | 500-5000 mW |
| Operating mode / pulse width | Q-switched | Pulsed | Pulsed |
| Beam quality | Confirm for this model | TEM00 | TEM00 |
Compare the MSL-AO-1064 with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide