Pulse energy, repetition rate, pulse width

EO-355-Subnano355 nm UV Q-switched pulsed laser

355 nm

EO-355-Subnano is a 355 nm Pulsed laser. Used for biomedicine, environmental monitoring, scientific research. Cooling: Air cooled. Key specifications: output / average power 1~100 mW, pulse energy 1~50 uJ, repetition rate 1-5 kHz(adjustable). View specifications, datasheet and enquiry options from Precisometer.

Specifications

EO-355-Subnano

19 specification rows

Output / average power1~100 mW
Pulse energy1~50 uJ
Repetition rate1-5 kHz(adjustable)
Pulse width<1.5 ns @1 kHz
Operating modeActively Q-switched
features of high single pulse energy, shortRep. rate / 1-5kHz (adjustable)
Beam divergence, full angle (mrad)<5mrad
monitoring,scientific
Cooled methodAir cooled
Warm-up time (minutes)<15
Operating temperature (℃)15-30
Power supply (110/220VAC)PSU-EO-Subnano
Beam / notesCooling: Air cooled
Wavelength (nm)355±1nm
Power stability (rms, 4 hours ±3℃)<5%, <3%
Pulse duration (ns)<1.5ns@1kHz
Rep. rate1-5kHz (adjustable)
Beam diameter (mm)~1.5mm
Beam height from base plate (mm)95

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Biomedicine

EO-355-Subnano: 355 nm emission determines compatible optics, coatings and detectors for Biomedicine. The catalogued beam parameter (<5mrad) helps predict how the source will focus and propagate through the instrument.

Environmental monitoring

EO-355-Subnano: 355 nm emission determines compatible optics, coatings and detectors for Environmental monitoring. The catalogued beam parameter (<5mrad) helps predict how the source will focus and propagate through the instrument.

Scientific research

EO-355-Subnano: 355 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (<5mrad) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect EO-355-Subnano to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (℃): 15-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <5mrad · Beam diameter (mm): ~1.5mm
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for EO-355-Subnano

What cooling does the EO-355-Subnano require?

Cooled method: Air cooled · Operating temperature (℃): 15-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the EO-355-Subnano deliver?

Beam divergence, full angle (mrad): <5mrad · Beam diameter (mm): ~1.5mm. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare EO-355-Subnano with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterEO-355-Subnano (current)MPL-FN-355MPL-F-355
Wavelength355 nm355 nm355 nm
Optical power / pulse energy1~100 mW1~30 mW1~100 mW
Operating mode / pulse width1-5 kHz(adjustable)10 Hz-3 kHz1-7 kHz
Beam quality<5mradTEM00TEM00