Back to Home

Pulse energy, repetition rate, pulse width

MPL-FN-355355 nm UV Q-switched pulsed laser

355 nm

MPL-FN-355 is a 355 nm Pulsed laser. Used for curing, micro-electronics, cd carving, laser medical treatment. Key specifications: output / average power 1~30 mW, pulse energy 1~15 uJ, repetition rate 10 Hz-3 kHz. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MPL-FN-355

16 specification rows

Wavelength355 nm
Output / average power1~30 mW
Pulse energy1~15 uJ
Repetition rate10 Hz-3 kHz
Pulse width~0.6 ns
Operating modePassively Q-switched
Power stability (rms, 4 hours, ±3°C)<5%, <3%, <2%
Transverse modeTEM00
M2<2.0
Beam diameter at the aperture (mm)~1.5
Warm-up time (minutes)<5
Operating temperature (℃)10-35
Power supply (100-240VAC)PSU-SR
Expected lifetime (hours)>10000
<2.0
Beam divergence, full angle (mrad)<1.5
Beam height from base plate (mm)27.4

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Curing

MPL-FN-355: 355 nm emission determines compatible optics, coatings and detectors for Curing. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Micro-electronics

MPL-FN-355: 355 nm emission determines compatible optics, coatings and detectors for Micro-electronics. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

CD carving

MPL-FN-355: 355 nm emission determines compatible optics, coatings and detectors for CD carving. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Laser medical treatment

MPL-FN-355: 355 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MPL-FN-355 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <2.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MPL-FN-355

What cooling does the MPL-FN-355 require?

Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MPL-FN-355 deliver?

Transverse mode: TEM00 · M2: <2.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MPL-FN-355 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMPL-FN-355 (current)MPL-F-355MPL-Q-355
Wavelength355 nm355 nm355 nm
Optical power / pulse energy1~30 mW1~100 mW1~150 mW
Operating mode / pulse width10 Hz-3 kHz1-7 kHz3-12 kHz
Beam qualityTEM00TEM00Near TEM00