Wavelength355 nm
Output / average power1~100 mW
Pulse energy1~40 uJ
Repetition rate1 Hz-20 kHz
Pulse width5-10 ns @<10 kHz
Operating modeActively Q-switched
Power stability (rms, 4 hours, ±3°C)<5%, <3%
Transverse modeTEM00
Beam diameter at the aperture 1/e2 (mm)~1.0
Polarization ratio>100:1, Horizontal (Vertical optional)
Operating temperature (℃)10-35
Power supply (100-240VAC)PSU-AOM-DL
Expected lifetime (hours)>10000
Pulse duration (ns)5-10ns @<10kHz
<1.2
Warm-up time (minutes)<10

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Material processing

AO-S-355: Material processing depends on how optical energy is delivered to the target; 355 nm emission governs absorption, while the listed temporal parameter (1~40 uJ) governs peak intensity and heat deposition.

Measure

AO-S-355: Measure benefits from a stable, focusable source. 355 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

Scientific research

AO-S-355: 355 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect AO-S-355 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · Beam diameter at the aperture 1/e2 (mm): ~1.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for AO-S-355

What cooling does the AO-S-355 require?

Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the AO-S-355 deliver?

Transverse mode: TEM00 · Beam diameter at the aperture 1/e2 (mm): ~1.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare AO-S-355 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterAO-S-355 (current)MPL-FN-355MPL-F-355
Wavelength355 nm355 nm355 nm
Optical power / pulse energy1~100 mW1~30 mW1~100 mW
Operating mode / pulse width1 Hz-20 kHz10 Hz-3 kHz1-7 kHz
Beam qualityTEM00TEM00TEM00